LCD Panel
RAID-x
TWO DRIVE DOWN
MULTIPLE
DOWN
SYSTEM
DOWN
Code ROM Error
System Halted
Work RAM Error
System Halted
Dispatch
Nesting Error
Divide or FPP or
Invalid Code Err
System
INTERRUPT Error
System
SBI INT Occur
System
RIE INT:0x000
System
AE INT:0x000
System
TRAP Error
Buffer Manager
Queue Error
Cache Buffer
Error 0x#######
Buffer Size
Error
Buffer Manager
Link Error
Corrective Action
Two drives failed. Check the LED in front for the defective drive. Refer to
chapter 6, "Drive Replacement", and replace the failed drive with a new drive.
You can stop the beeping by pressing the mode button.
Two or three drives failed. Check the LED in front for the defective drive.
Refer to chapter 6, "Drive Replacement", and replace the failed drive with a
new drive.
You can stop the beeping by pressing the mode button.
Three or more drives failed. Check the LED in front for the defective drive.
Refer to chapter 6, "Drive Replacement", and replace the failed drive with a
new drive.
You can stop the beeping by pressing the mode button.
Program ROM cannot be read. Shut off the TeraStation, wait 10 seconds, then
turn it back on. If the error still remains, contact Buffalo technical support.
A work memory error occurred on the array controller. Shut off the
TeraStation, wait 10 seconds, then turn it back on. If the error still remains,
contact Buffalo technical support.
Internal error. The TeraStation cannot be accessed. Contact Buffalo technical
support.