Fault codes
(cont.)
Fault code
System character-
on the dis-
istics
play
EA
Burner in a fault
state
Eb
Burner in a fault
state
EC
Burner in a fault
state
Ed
Burner in a fault
state
F0
Burner blocked
F1
Burner in a fault
state
F2
Burner in a fault
state
F3
Burner in a fault
state
Cause
Measures
The ionisation
Check the ionisation
current lies out-
electrode and cable.
side the permissi-
Press "E RESET".
ble range during
calibration
Heat draw-off re-
Initiate heat draw-off
peatedly too low
and trigger manual cali-
during calibration
bration (see page 112)
Press "E RESET".
The ionisation
Check the ionisation
current lies out-
electrode and cable.
side the permissi-
Press "E RESET".
ble range during
calibration
Internal fault
Replace the control unit.
Internal fault
Replace the control unit.
Flue gas tem-
Check the heating sys-
perature limiter
tem water level. Vent the
has responded.
system.
Press "E RESET" after
the flue gas system has
cooled down.
The temperature
Check the heating sys-
limiter has re-
tem water level. Check
sponded.
the circulation pump.
Vent the system. Check
the temperature limiter
and connecting cables.
Press "E RESET".
Flame signal is al-
Check the ionisation
ready present at
electrode and connect-
burner start.
ing cable.
Press "E RESET".