Complete The Procedure; Replace A Scsi Disk Drive - Bull ESCALA POWER6 PL1660R Manual

Customer-installable features
Hide thumbs Also See for ESCALA POWER6 PL1660R:
Table of Contents

Advertisement

Figure 52. Installing a disk drive in a model or 11D/20

Complete the procedure

1. Replace the front cover. For instructions on replacing the cover, select the appropriate procedure from
the following list:
v hwip2frontbezelon.dita#hwip2frontbezelon
v "Install the front cover on the model " on page 311
v "Install the front cover on the 11D/20 expansion unit" on page 310
v If you have a front cover from any other models, install the front cover.
2. Install or close the system, expansion unit or rack front door.
3. Reconnect all system power cables.
4. Reconnect the system to the power supply by plugging it in.
5. Start the system or logical partition. For instructions, see "Start the system or logical partition" on
page 300.
6. If the system or logical partition that controls the disk drive you replaced is running AIX, verify that
the disk drive is working as described in "Verify an installed feature or replaced part on an AIX
system or logical partition" on page 320. If it is not possible to run online diagnostics, for example if
you replaced the root volume group (rootvg) disk drive, use standalone diagnostics as described in
"Verify an installed part using stand-alone diagnostics" on page 324.
7. To rebuild the data on the replacement disk drive, select the operating system for the system or
logical partition that controls the disk drive:
v "Rebuild data on a replacement disk drive using AIX" on page 84
v "Rebuild data on a replacement disk drive using Linux" on page 85

Replace a SCSI disk drive

You might need to replace a Small Computer System Interface (SCSI) disk drive in a system or expansion
unit. Use the procedure in this section to perform this task.
58
Customer-Installable Features for the 17M/MA

Advertisement

Table of Contents
loading

Table of Contents