Error Code Troubleshooting - Graco E-Flo DC Series Instructions - Parts Manual

Hide thumbs Also See for E-Flo DC Series:
Table of Contents

Advertisement

Error Code Troubleshooting

Error codes can take three forms:
• Alarm
: alerts you to the alarm cause and shuts
down the pump.
• Deviation
: alerts you to the problem, but pump
may continue to run past the set limits until the
system's absolute limits are reached.
• Advisory: information only. Pump will continue to
operate.
NOTE: On Advanced motors, flow (K codes) and
pressure (P codes) can be designated as alarms
or deviations. See Setup Screen 4 in the Control
Module Manual.
Applicable
Blink Code
Motor
Advanced
1–2
Advanced
None
Basic and
Advanced
Advanced
None
Advanced
1–3
Advanced
None
Advanced
1–4
Advanced
None
Basic and
Advanced
Basic and
Advanced
Advanced
2–3
Advanced
None
3A2526D
Display Code
K1D?
K2D?
1
K4D?
K3D?
P1I?
P2I?
P4I?
P3I?
2
V1I?
3
V4I?
CAD?
CAC?
CONTINUED ON THE NEXT PAGE.
NOTE: In the error codes listed below, an "X" means
the code is associated with the display only.
NOTE: In the error codes listed below, a "?" in the
code is a placeholder for the unit number where the
event occurred.
NOTE: The blink code is displayed using the power
indicator on the motor. The blink code given below
indicates the sequence. For example, blink code 1–2
indicates 1 blink, then 2 blinks; the sequence then
repeats.
NOTE: A blink code of 9 is not an error code, but
an indicator of which pump is active (
has been pushed, see Run Screen 1 in the Control
Module Manual).
Alarm or
Deviation
Alarm
Flow is below minimum limit.
Deviation
Flow is below minimum limit.
Alarm
Flow exceeds maximum target; also
indicates pump runaway condition exists.
Deviation
Flow exceeds maximum target; also
indicates pump runaway condition exists.
Alarm
Pressure is below minimum limit.
Deviation
Pressure is below minimum limit.
Alarm
Pressure exceeds maximum target.
Deviation
Pressure exceeds maximum target.
Alarm
Brown out; voltage supplied to motor is too
low.
Alarm
Voltage supplied to motor is too high.
Alarm
Unit detects a loss of CAN communication.
This alarm is only logged. No flashing
alarm appears on the display, but the blink
code does occur.
Alarm
Display detects a loss of CAN
communication. Flashing alarm
appears on the display, and the blink code
occurs.
Error Code Troubleshooting
softkey
Description
17

Advertisement

Table of Contents
loading