1070 066 032 / 03
Servodyn-D
VMA..KR, VMA..B,C,D,F and DM/DS error displays
F code
Error
Meaning
display
number
F70
2362
Flash rating plate: Parameter set 2: Distance between reference marks = 0
2363
Flash rating plate: Parameter set 2: Thrust constant value 1 = 0
2364
Flash rating plate: Parameter set 2: EMF constant = 0
2365
Flash rating plate: Parameter set 2: Series inductance = 0
2366
Flash rating plate: Parameter set 2: Shunt inductance = 0
2367
Flash rating plate: Parameter set 2: Leakage inductance primary winding = 0
2368
Flash rating plate: Parameter set 2: Leakage inductance secondary winding = 0
2369
Flash rating plate: Parameter set 2: Second. resistance = 0
F71
0
Inverter-Initialization error – Detailed fault documentation unavailable at this
F72
0
Configuration error; Motor / module combination not functional
F91
0
Personality error; Check proper seating of PM; Replace module
F92
0
I2C-Bus runtime error; Defective module
F95
0
I-controller synchronization error; Defective module
F96
0
Speed controller, plausibility error – Detailed fault documentation unavailable
2
Drive blocked in negative direction
3
Too little current –> Performance interruption
4
Motor overspeed –> Reverse acceleration
5
Too little current –> Performance interruption
8
Timeout torque limitation
18
Drive blocked in positive direction
19
Too little current –> Performance interruption
20
Motor overspeed –> Reverse acceleration
21
Too little current –> Performance interruption
128
Speed controller synchronization error
F97
0
VM shutdown due to FGZ shutdown
F98
0
ASTS shutdown
Electric Drives
Bosch Rexroth AG
and Controls
4–27