VMA..KR, VMA..B,C,D,F and DM/DS error displays
Displays flash
Error
alternately.
The drive has switched off.
Assignment mains connection mod-
ule – VM
Mains connection module and supply mod-
ule do not have the same power output
stage.
CAN bus only:
Internal command active
The controller must not enable the drive at
this time.
Runtime Personality Module
Runtime I
Stacking error
Inadmissible memory access
Synchronization error I controller
Internal synchronization of the VM firm-
ware disturbed
Speed controller plausibility error
VM error
Torque is immediately turned off because
of an operating fault (e.g. under-/overvol-
tage)
Electric Drives
and Controls
2
C-Bus
Servodyn-D 1070 066 032 / 03
Action
D Combine compatible modules
D Check stable position of personality
module
D Replace personality module
D Replace module
D Replace module
D Replace module
D Replace module
For details of the fault, refer to
.
S-0-0095, cf. page 4–14.
D Check motor cable
D Switch modules off because of danger-
ous electrical voltage!
Check DC link connection,
check DC link voltage
D Motor stalled
D Turn off torque reduction
D For more details, refer to P-0-0010
D Check error message on VM
D Clear error by "Reset Diagnostics class
1 error"
Check whether the fan on the bot-
.
tom side of the module has failed.