1070 066 032 / 03
Servodyn-D
VMA..KR, VMA..B,C,D,F and DM/DS error displays
Displays flash
Error
alternately.
The drive has switched off.
VM off with active control
Motors are shut down because of a shut-
down command
Status message for DM with analog inter-
face, MC, CAN bus and PROFIBUS-DP if
the VM is switched off while the FG enable
signal is high.
Other runtime errors
Electric Drives
Bosch Rexroth AG
and Controls
Action
D Switch VM on
D Check EMERGENCY-STOP
D Clear error by "Reset Diagnostics class
1 error"
D Replace module