1070 066 032 / 03
Servodyn-D
VMA..KR, VMA..B,C,D,F and DM/DS error displays
F code
Error
Meaning
display
number
F70
1253
Motor rating plate: Parameter set 1: Speed: Maximum = 0
1254
Motor rating plate: Parameter set 1: Force: Nominal thrust = 0
1255
Motor rating plate: Parameter set 1: Force: Standstill thrust = 0
1256
Motor rating plate: Parameter set 1: Force: Max. thrust = 0
1257
Motor rating plate: Parameter set 1: Primary Resistance = 0
1258
Motor rating plate: Parameter set 1: Transportable load = 0
1259
Motor rating plate: Parameter set 1: Signal periods length = 0
1260
Motor rating plate: Parameter set 1: Distance between reference marks = 0
1261
Motor rating plate: Parameter set 1: Step distance = 0
1262
Motor rating plate: Parameter set 1: Distance between reference marks = 0
1263
Motor rating plate: Parameter set 1: Thrust constant value 1 = 0
1264
Motor rating plate: Parameter set 1: EMF constant = 0
1265
Motor rating plate: Parameter set 1: Series inductance = 0
1266
Motor rating plate: Parameter set 1: Shunt inductance = 0
1267
Motor rating plate: Parameter set 1: Leak inductance primary winding = 0
1268
Motor rating plate: Parameter set 1: Leak inductance secondary winding=0
1269
Motor rating plate: Parameter set 1: Second. resistance = 0
1270
Multiturn value: Different rating plate info & Mfg. specifications; Motor set 1
1271
Singleturn value: Different rating plate info & Mfg. specifications; Motor set 1
1272
Encoder pulses: Different rating plate info & Mfg. specifications; Motor set 1
1273
Singleturn value: Different rating plate info & Mfg. specifications; Motor set 1
1274
Encoder pulses: Different rating plate info & Mfg. specifications; Motor set 1
1275
No. of ref. marker periods:Different rating plate info & Mfg. specif.;Motor set1
1276
Encoder pulses: Different rating plate info & Mfg. specifications; Motor set 1
1277
Encoder pulses: Different rating plate info & Mfg. specifications; Motor set 1
1278
Signal period length:Different rating plate info &Mfg. specifications;Motor set1
1279
Steps distance : Different rating plate info & Mfg. specifications; Motor set 1
1280
Signal period length:Different rating plate info& Mfg. specifications;Motor set1
1281
Signal period length:Different rating plate info&Mfg. specifications;Motor set 1
1282
Ref. marker spacing:Different rating plate info & Mfg. specifications;Motor set1
1283
Signal period length:Different rating plate info &Mfg. specifications;Motor set1
1284
Ref. marker spacing:Different rating plate info & Mfg. specifications;Motor set1
1285
1st Ref. marker position:Different rating plate info & Mfg. specific.;Motor set1
1286
Encoder pulses: Different rating plate info & Mfg. specifications; Motor set 1
1287
Encoder pulses: Different rating plate info & Mfg. specifications; Motor set 1
1301
Motor rating plate: Parameter set 2: Motor type = 0
1302
Motor rating plate: Parameter set 2: Version number = 0
1303
Motor rating plate: Parameter set 2: Encoder pulses = 0
1304
Motor rating plate: Parameter set 2: Nominal velocity = 0