VMA..KR, VMA..B,C,D,F and DM/DS error displays
F code
Error
Meaning
display
number
F13
0
Excessive system deviation; Drive is unable to follow defined nominal value
1
Monitoring error dual encoder
2
Excessive system deviation spindle
F14
0
Positioning threshold exceeded;
F15
0
Software speed monitoring: Overspeed in Standard mode
3
Software speed monitoring: Overspeed in Setup mode
5
Software speed monitoring: Overspeed in zero-speed monitoring
F16
0
Hardware speed monitoring: Overspeed in Standard mode
3
Hardware speed monitoring: Overspeed in Setup mode
5
Hardware speed monitoring: Overspeed in zero-speed monitoring
F30
0
Overvoltage in DC link; DC link voltage > 670 V
F35
0
Power supply fault
F36
0
Faulty external 24 VDC power; 24 V module power outside of permissible range
F46
0
RSU channel error – detailed fault documentation unavailable at this time
16
RSU: Hardware speed monitoring in Standard mode
17
RSU: Hardware speed monitoring in non-standard operation
32
RSU: Software speed monitoring in Standard mode
33
RSU: Software speed monitoring in non-standard operation
64
RSU: Channel error timeout expired in Standard mode
65
RSU: Channel error timeout expired in non-standard mode
128
RSU: Maximum dead-man interval expired in Standard mode
129
RSU: Maximum dead-man interval expired in non-standard mode
2048
RSU: Data comparison error in Standard mode
2049
RSU: Data comparison error in non-standard mode
4096
RSU: Data error, sensor calibration in Standard mode
4097
RSU: Error: Data & sensor calibration in non-standard mode
6144
RSU: Error: Data & sensor calibration in Standard mode
6145
RSU: Data error, sensor calibration in non-standard mode
8192
RSU: Error, high-level lockout in Standard mode
8193
RSU: Error, high-level lockout in non-standard mode
8432
RSU: Error, Program process monitoring in Standard mode
8433
RSU: Error, high-level lockout in non-standard mode
F60
0
I2C-Initialization error – Detailed fault documentation unavailable at this time
F61
0
ADC-Initialization error – Detailed fault documentation unavailable at this time
F62
0
PWM – Initialization error; Defective module
F63
0
Initialization error – SERCOS tables
F64
0
Overcurrent – Initialization error; Defective module