4–14
Bosch Rexroth AG
VMA..KR, VMA..B,C,D,F and DM/DS error displays
4.5.1

List of error number in parameter P-0-0095

F code
Error
Meaning
display
number
F03
0
Faulty option module in drive slot
F04
0
Overcurrent; Permitted peak current exceeded
F06
0
Realtime error; Excessive computer load; Defective module (watchdog)
1
Realtime error; Watchdog I-controller has responded
2
Realtime error; Watchdog N-controller has responded
4
Realtime error; Watchdog X-controller has responded
F07
0
Heat sink overtemperature; Heat sink temperature > 80°C
F08
0
Motor overtemperature; Motor winding > 145°C; Defective temperature probe
F10
0
SERCOS interface communication error; Detailed diagnostics at S-0-0014
F11
0
Encoder fault; Detailed fault documentation unavailable at this time
1
Motor encoder: Encoder signal voltage amplitude too low
2
Motor encoder: Error in captured analog value
4
Motor encoder: Two active counting slopes
8
Motor encoder: Excessive RPM upon absolute-value capture
16
Motor encoder: Short-circuit between encoder signals and GND, or power supply
96
Motor encoder: Loose encoder (only in conjunction with RSU software)
160
Motor encoder: Loose encoder (only in conjunction with RSU software)
289
Motor encoder: Broken encoder coupling; Wrong encoder connected
16384
Motor encoder: Wrong marker distance
32768
Processing error in RSU software; Function: Redundant encoder monitoring
50001
OM3 encoder: Encoder signal voltage amplitude too low
50004
OM3 encoder: Two active counting slopes
50016
OM3 encoder: Short-circuit between encoder signals and GND, or power supply
50256
OM1/2 encoder: Two active counting slopes
50512
OM1/2 encoder: Too many pulses per RPM
51024
OM1/2 encoder: Too few pulses per RPM
52048
OM1/2 encoder: Encoder signals A and AN not inverted
54096
OM1/2 encoder: Encoder signals B and BN not inverted
58192
OM1/2 encoder: Encoder signals R and RN not inverted
66384
External encoder: Wrong marker distance
F12
0
Tracking error (zero-speed monitoring); Axis moves without traversing command
Electric Drives
and Controls
Parameter P-0-0095 contains additional error numbers which provide
for a more detailed analysis of various error displays of the modules.
The following table is based on the F code display and lists the meaning
of the error numbers:
Servodyn-D 1070 066 032 / 03