NOTE: The water heat rate may change in the below conditions:
· When the outdoor temperature is below 15°C (59°F).
· If the cover is not in position when the heating function is activated.
NOTE: To display the current water temperature, run the filter system for at least a minute. The water temperature as tested by an external
thermometer may vary from the temperature as displayed on the spa panel due to the differing positions of the measurement devices.
Alarms
Causes
The water flow
sensors work without
pressing the filter or
heat button.
After starting or
during the functions
of filtering or/and
heating, the water
flow sensors do not
detect water flow.
The pump's
thermometer reads the
water temperature
below 4°C (40°F).
The pump's
thermometer reads the
water temperature
over 50°C (122°F).
The pump's
thermometer
connections have
issues.
The manual reset
thermal cut-out has
a problem.
104°C (219°F) Fuse
fault.
Hign salt alarm.
Low salt alarm.
Water leakage inside
the pump.
S-S-003587/21x28.5cm/54138NN 54144NN 欧规SPA说明书/JS-YF-2015-B-04514/英
Reasons
1. The water flow sensors'
flags didn't fall back into
the correct position.
2. The water flow sensors
are broken.
1. You forgot to remove the 2
stopper caps from inside the pool.
2. The filter cartridges are dirty.
3. Activate the filter or heat system
and put your hand in front of the
outlet pipe inside the pool to
check if you can feel water.
flowing out.
a. If no water flows out the water
pump is broken.
b. Water flows out but the alarm
appears, the water flow sensors
are broken.
1. The water temperature is lower
than 4°C (40°F).
2. If the water temperature is
higher than 7°C (44.6°F), the
pump's thermometer is broken.
1. The water temperature is over
50°C (122°F).
2. If the water temperature is lower
than 45°C (113°F), the pump's
thermometer is broken.
1. The pump's thermometer
connectors are not working
properly.
2. The pump's thermometer is
broken.
The manual reset thermal cut-out
has been tripped.
The fuse is disconnected.
Too much salt has been added or
too much water has evaporated.
Not enough salt for sanitizing.
The System has detected
some water leakage inside
14
the pump.
Solutions
1. Unplug the pump, strike the side of the pump
firmly (but not violently), and plug it back in.
2. Contact your local Bestway Aftersales
Service Center for instructions.
1. Remove the two stopper caps before starting the
heating system. Refer to the Assembly section in the
User's Manual.
2. Remove the filter set from inside the pool and push
the filter or heat button. If no alarm appears, clean or
change the filter cartridges and re-install the filter set
inside the pool.
3. Contact your local Bestway Aftersales Service
Center for instructions.
1. The spa is not designed to operate with water
temperatures lower than 4ºC (40°F). Unplug the
pump and only re-start the pump when the water
temperature reaches 6°C (43°F).
2. Contact your local Bestway Aftersales Service
Center for instructions.
1. The spa is not designed to operate with water
temperatures greater than 40°C (104°F). Unplug
the pump and only re-start the pump when the
water temperature reaches 38°C (100°F) or
lower.
IMPORTANT: Before you re-start
the pump, push the pump's reset
button.
2. Contact your local Bestway Aftersales Service
Center for instructions.
Contact your local Bestway Aftersales Service Center
for instructions.
1. Unplug the pump and push the reset button, then plug
the pump back in.
2. In case the alarm still remains, check the RESET
BUTTON section in manual.
3. Contact your local Bestway Aftersales Service Center
for instructions.
Contact your local Bestway Aftersales Service Center
for instructions.
1. Follow the instructions in operation part to remove the salt.
2. Contact your local Bestway Aftersales Service Center
for instructions.
1. Follow the instructions in operation part to add salt in the water.
2. Contact your local Bestway Aftersales Service Center for
instructions.
Contact your local Bestway Aftersales Service Center
for instructions.
S-S-003587