OPERATION

1.
2.
3.
Adjustment of Jet Nozzle
5
.
Heating Reset
When using the Lay-Z-Spa for the first
time, or after a long period of inactivity,
be sure to press the reset button on the
pump using a small and thin object.
RESET BUTTON
IMPORTANT INSTRUCTIONS FOR USE
If the temperature on the control panel (or the water
temperature) has not changed 4-5 hours after
activation of the heating system, use a thin object to
press the RESET BUTTON and restart the heating
system.
IMPORTANT:
The heating System will not
operate if the outside temperature is above 40ºC
(104 ºF) or if the Lay-Z-Spa is under direct sunlight.
Under these conditions, please wait until a cooler
time of day before pressing the RESET BUTTON with
a thin object and restart the heating System. This
operation must be repeat everytime when the pump
is under above conditions.
S-S-003587/21x28.5cm/54138NN 54144NN 欧规SPA说明书/JS-YF-2015-B-04514/英
90°
4.
Instruction of Salt Chlorinator System
NOTE:
add salt in the water follow the below steps.
(1). Turn on the HydroJet System to start the water
(2). Keep the Salt Chlorinator System turned off.
(3). Add 4.4 lbs / 2 kg of salt into the SPA pool
(4). When all the salt is dissolved, turn on the Salt
+
NOTE:
Chlorinating process.
-
RESET
To use the Salt Chlorinator System, please
circulation.
gradually, use only sodium chloride (NaCl) salt that
is at least 99.9% pure or water conditioning salt
pellets (the compressed forms of evaporated salt -
it will take longer to dissolve).
Chlorinator System and set the working duration
(refer to Salt Chlorinator System Button instruction).
Attach the spa cover during the Salt
Add Salt if Salt Level is too low
If not enough salt has been added, the panel
displays an "E11" error code.
(1). Unplug the spa and then plug it back in.
(2). Turn on the HydroJet System.
(3). Gradually add and dissolve 1.1 lbs/0.5 kg of salt.
(4). Start the Salt Chlorinator System.
(5). If the "E11" Code remains, follow the above
steps until the "E11" error code disappears.
Remove Salt if Salt level is too high
If too much salt has been added, the panel displays an
"E10" error code.
(1). Unplug the spa.
(2). Drain and refill approximately 20% of the water.
(3). Start the Salt Chlorinator System.
(4). If the "E10'' Code remains, follow the above steps
untill the "E10" alarm disappears.
12
S-S-003587