WAGNER EvoMotion 5-125 Translation Of The Original Operating Manual page 37

Piston pump, delivery volume 125 cm3
Hide thumbs Also See for EvoMotion 5-125:
Table of Contents

Advertisement

VERSION 01/2018
8.2.3.2 PRODUCT HOSES, PIPES AND COUPLINGS
The service life of the complete hoses between product pressure generator and application
device is reduced due to environmental influences even when handled correctly.
Check hoses, pipes, and couplings every day and replace if necessary.
Before every commissioning, check all connections for leaks.
Additionally, the operator must regularly check the complete hoses for wear and
tear as well as for damage at intervals that he/she has set. Records of these checks
must be kept.
Undamaged complete hoses are to be replaced when one of the two following
intervals has been exceeded:
−6 years from the date of the hose crimping (see fitting embossing).
−10 years from the date of the hose imprinting.
Fitting embossing
xxx bar
yymm
XX
Hose imprinting
Wagner
yymm
xxx bar (xx MPa)
e.g., 270 bar (27 MPa)
XX
DNxx (e.g., DN10)
ORDER NUMBER DOC 2316596
Meaning
Pressure
Crimping date (year/month)
Internal code
Meaning
Name / Manufacturer
Date of manufacture (year/month)
Pressure
Internal code
Nominal diameter
37