WAGNER EvoMotion 5-125 Translation Of The Original Operating Manual page 28

Piston pump, delivery volume 125 cm3
Hide thumbs Also See for EvoMotion 5-125:
Table of Contents

Advertisement

VERSION 01/2018
Grounding scheme (example)
Ex zone
B_00304
Part / workstation
Pump
Product tank
Conveyor
Spray booth
Spraying stand
Safe operation of the pump is only guaranteed with a grounding
connection.
Connect all grounding cables using a short and direct route.
Procedure:
1 Screw on grounding cable with eyelet.
2 Clamp the grounding cable clip to a grounding connection on site.
3 Ground the product tank to an on-site grounding connection.
4 Ground the other parts of the system to an on-site grounding connection (16mm2;
AWG 6).
Ex zone
All devices and equipment must be suitable for use in potentially explosive areas.
All paints, flushing agents and waste tanks have to be electrically conductive.
All tanks must be grounded.
ORDER NUMBER DOC 2316596
Product
tank
Floor, static dissipative
Cable cross sections
4 mm
; AWG 12
2
6 mm
; AWG 10
2
16 mm
; AWG 6
2
16 mm
; AWG 6
2
16 mm
; AWG 6
2
Conveyor
Spraying stand
Work piece
R max < 1 MΩ
Grounding
cable
B_06878
28