Electrical installation
Model
Market
Europe
Stillbath
North America
Japan
Europe
Hydrosound
North America
Japan
Europe
Hydromassage
North America
Japan
•
First check that the electrical supply
corresponds with the information on
the label on the backside of the
panel.
•
The unit must be permanently
installed.
•
The unit must be continuously
powered and connected to separate
fuse with ground fault circuit
interrupter.
•
Main switch must be placed close to
the tub and visable for the user.
•
Power supply is activated via the
main switch.
•
Fuses according to EN60898.
DIP Switches for Autofill
The model is equipped with dip switches,
which are located on the PCB and can be
adjusted as in the tables below:
PCB located on the backside of the panel
front.
1
OFF
Not used
2
ON
Auto-fill activated
2
OFF
Auto-fill deactivated
3
OFF
0 seconds*
4
OFF
3
ON
60 seconds*
4
OFF
3
OFF
120 seconds*
4
ON
3
ON
180 seconds*
4
ON
*the amount of seconds of extended filling time
from that the 0-level is fulfilled.
6
Voltage
230/240V single phase AC
120V single phase AC
100V single phase AC
230/240V single phase AC
120V single phase AC
100V single phase AC
230/240V single phase AC
120V single phase AC
100V single phase AC
The unit shall be electrically connected
with the following equipment
(not included in delivery):
•
Separate fuse.
•
Ground fault circuit
interrupter (10mA)
•
Safety switch, according to
regulations and local codes.
•
Mains cable
(3x16AWG / 3x1.5 mm
All electrical installations must comply
with the US National Electrical Code and
the Canadian Electrical Code respectively.
DIP Switch for Cleaning
6
ON
Automatic hydroclean
Time set for effect of
cleaning
5
ON
10 minutes
5
OFF
2 minutes
6
OFF
No hydroclean
DIP Switch Hydro/No Hydro
7
ON
Hydrosound/
Hydromassage
7
OFF
Stillbath
Fuse
Frequency
(slowblow)
50Hz
6A
60Hz
10 A
50/60 Hz
10 A
50Hz
6 A
60Hz
10 A
50/60 Hz
10 A
50Hz
6 A
60Hz
10 A
50/60 Hz
10 A
Connect the wires as described below:
EUROPE
Neutral to the blue wire (N)
Phase to the brown wire (L)
Protective earth to
the yellow/green wire (PE)
USA
Neutral to the white wire (NEUT)
Phase to the black wire (HOT)
2
)
Protective earth to
the green wire (GND)
Power
consumption
max.700 VA
max. 700 VA
max. 700 VA