OperationalMatrixfortheModelDO600
Function/
Power
Mode
Resulting
Status
Setting
Action
On/Off
Any
Any
WaterSaturated
On
Any
AirCalibration
ZeroCalibration
On
Any
StoreReading
On
Any
HoldRelease
WhileIn
On
Hold
Mode
EnterMemory
Retrieval
On
Any
ScrollStored
Memory
On
Readings
Recall
ExitMemory
Memory
On
Retrieval
Recall
ClearStored
Any
On
Measure‐
Memory
mentMode
Change
Measurement
On
Any
Mode
EnterSalinity
On
Any
Compensation
Changing
Salinity
On
SAL
Compensation
ExitSalinity
Compensation
On
SAL
EnterAltitude
Compensation
Anyor
On
SAL
Changing
Altitude
On
Ald
Compensation
ExitAltitude
Compensation
On
Ald
Change
Temperature
n/a(off
Off
Units
mode)
Override
AutopowerOff
On
Any
DefaultReset
n/a(off
Off
mode)
RequiredButtonPressSequence
MomentarypressoftheON/OFFbutton
PlaceElectrodeinCalibrationCap
Press&holdCAL/RECALLbuttonfor2seconds
PlaceElectrodeinZeroSolution,waitforstabilityPress
&holdCAL/RECALLbuttonfor2seconds
MomentarypressoftheMODE/HOLDbutton
MomentarypressoftheMODE/HOLDbutton
MomentarypressoftheCalbuttonfollowedby
amomentarypressoftheMODE/HOLDbutton
(w/in4seconds)
MomentarypressoftheMODE/HOLDbutton
MomentarypressoftheCAL/RECALL
PressandholdtheON/OFFbuttonfor4seconds
PressandholdtheMODE/HOLDbuttonforat
leasttwoseconds(themodeswillscrolluntil
thebuttonisreleased)
PressandreleasetheCAL/RECALLbuttontwice
(momentary)insuccession(DisplaysSAL)
MomentarypressoftheMODE/HOLDbutton
(eachbuttonpressincreasestheratioby1ppt
(partperthousand),thevaluecyclesfrom0to
50)
PressandreleaseCAL/RECALLbuttonfor2
secondstoenterAltitudeCompensation,Or
PressandreleaseCalButtononemoretimeto
entermeasurementmode
PressCAL/RECALLtwice(momentary).Unit
entersSalinityMode.PressCAL/RECALLfor2
secondstoenterAltitudeCompensationMode.
(DisplaysAld)
MomentarypressoftheMODE/HOLD
button(eachbutton‐pressincreasesaltitudeby
1,000ft,thevaluecyclesfrom0to20)
MomentarypressCAL/RECALLbuttontoexit
andsavechanges.
PressandholdtheCAL/RECALLbuttonthen
momentarilypresstheON/OFFbutton.Release
theCAL/RECALLbuttonafterthe"SELFCAL"
lights
PressCAL/RECALLbutton(momentary)then
simultaneouslypressandholdtheMODE/HOLD
andON/OFFbuttonsforfor2seconds.
SimultaneouslypressON/OFF,CAL/RECALLand
MODE/HOLDmomentarily."dFLt"willbe
displayed.
12
Comments
Alsoworkswithprobe
removed(Calatzerocurrent)
Storesandholdsreading
"HOLD"displayed
Ifnodataisstoredin
memory,"End"isdisplayed
briefly,andthenreturnsto
lastmode.
"clr"isdisplayed.
Itisnecessarytopressthe
CAL/RECALLbuttontosave
changes.Iftheunittimesout,
nochangesaresaved.
Unittimesoutin5
secondsifnobuttonis
pressed,revertsto
previousmode.
Itisnecessarytopressthe
CAL/RECALLbuttontosave
changes.Iftheunittimesout,
nochangesaresaved.
DO600-en-GB_V7.4 12/16
Need help?
Do you have a question about the ExStik DO600 and is the answer not in the manual?
Questions and answers