Table 4-4 Waveform Information - Prodigit 3260A Series Operation Manual

High power load
Table of Contents

Advertisement

PRODIGIT
BANK
Purpose: : : :
To set waveform bank.
Command syntax: : : : BANK{SP}{d}{;|NL}
Description: : : :
This command is to set the waveform bank desired to be selected.
1. waveform bank 0~2 are sine wave.
2. waveform bank 3~8 are P.F..
3. waveform bank 9 are square wave.
4. waveform bank 10 is DC.
5. There are five (5) waveform information for each waveform bank, therefore, there
For Example: : : :
a. BANK 1 ; To set waveform bank 1.
b. BANK 10 ; To set waveform bank 10.
sine wave
C.F.= 2.0
C.F.= 2.5
C.F.= 3.5
C.F.= 2.0
C.F.= 2.5
C.F.= 3.5
square wave
WAVE
Purpose: : : :
To set waveform.
Command syntax: : : : WAVE{SP}{m}{;|NL}m:0~4
Description: : : :
This command is to set the current C.F. at CC MODE (Peak Value Factor).
This command works only at CC MODE. When BANK varies, these 5 sets of C.F. will
at the same time define different C.F. as shown in Table 4-4. For details, please refer
to 3260A Operation Manual.
For Example: : : :
a.WAVE 1 ; To set 2nd set C.F.
b.WAVE 4 ; To set 5th set C.F.
is a total 55 waveform information for eleven (11) waveform banks. Waveform
information is shown in Table 4-4.
Wave
From Bank
0
1
2
3
4
5
6
7
8
9
DC
10
d:0~10
A
B
2.0
√2
1.5
1.6
3.0
3.1
P.F.=-0.85 P.F.=-0.80 P.F.=-0.75 P.F.=-0.70 P.F.=-0.65
P.F.=-0.70 P.F.=-0.65 P.F.=-0.60 P.F.=-0.50 P.F.=-0.40
P.F.=-0.50 P.F.=-0.45 P.F.=-0.40 P.F.=-0.35 P.F.=-0.30
P.F.= 0.85 P.F.= 0.80 P.F.= 0.75 P.F.= 0.70 P.F.= 0.65
P.F.= 0.70 P.F.= 0.65 P.F.= 0.60 P.F.= 0.50 P.F.= 0.40
P.F.= 0.50 P.F.= 0.45 P.F.= 0.40 P.F.= 0.35 P.F.= 0.30
1.0
1.1
2dc
√2dc

Table 4-4 waveform information

3260A Series Operation Manual 45
C
D
2.5
3.0
1.7
1.8
3.2
3.3
1.2
1.3
2.5dc
3.0dc
E
3.5
1.9
3.4
1.4
3.5dc

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3260a32601a3261a32611a32613a32612a ... Show all

Table of Contents