38 PRODIGIT
4-3 3260A Series GPIB/RS-232C COMMAND LIST
Function
SET AUTO FREQUENCY
DETECT ON/OFF
SET SYNC ON/OFF
SET SENC ON/OFF
SET WATT ON/OFF
SET BANK
SET WAVE
SET FREQUENCY
SET VOLTAGE LOW LIMIT
SET VOLTAGE HIGH LIMIT VH{SP}{NR2}{;|NL}
SET CURRENT LOW LIMIT
SET CURRENT HIGH LIMIT IH{SP}{NR2}{;|NL}
SET WATT LOW LIMIT
SET WATT HIGH LIMIT
SET VA LOW LIMIT
SET VA HIGH LIMIT
SET CURRENT
SET RESISTANCE
SET LINEAR CURRENT
SET LOAD ON/OFF
SET LEVEL LOW/HIGH
SET PRESENT ON/OFF
SET MODE
SET STORE STATE
SET RECALL STATE
SET REMOTE STATE
SET LOCAL STATE
REMARK :
1. CURRENT ENGINEERING UNIT : A
2. VOLTAGE ENGINEERING UNIT : V
3. RESISTANCE ENGINEERING UNIT :
AFREQ{SP}{0|1|OFF|ON}{;|NL}
SYNC{SP}{0|1|OFF|ON}{;|NL}
SENS{SP}{0|1|OFF|ON}{;|NL}
WATT{SP}{0|1|OFF|ON}{;|NL}
BANK{SP}{d}{;|NL}
WAVE{SP}{m}{;|NL}}
FREQ{SP}{NR2}{;|NL}
VL{SP}{NR2}{;|NL}
IL{SP}{NR2}{;|NL}
WL{SP}{NR2}{;|NL}
WH{SP}{NR2}{;|NL}
VAL{SP}{NR2}{;|NL}
VAH{SP}{NR2}{;|NL}
CURR:
{LOW|HIGH|A|B}{SP}{NR2}{;|NL}
RES:{LOW|HIGH|A|B}{SP}{NR2}{;
|NL}
LIN:{A|B}{SP}{NR2}{;|NL}
LOAD{SP}{0|1|OFF|ON}{;|NL}
LEV{SP}{0|1|LOW|HIGH}{;|NL}
PRES{SP}{0|1|OFF|ON}{;|NL}
MODE{SP}{0|1|2|CC|CR|LIN}{;|NL}
STORE{SP}{m}{;|NL}
RECALL{SP}{m}{;|NL}
REMOTE{;|NL}
LOCAL{;|NL}
Table 4-1 GPIB/RS-232C SETTING COMMAND SUMMARY
Setting Command
Command
Format
d:0 ~ 10
m:0 ~ 4
NR2:###.#####
NR2:###.#####
m:1 ~ 5
m:1 ~ 5
Omly RS232 cmd
Omly RS232 cmd