Store / Recall Operation - Prodigit 3260A Series Operation Manual

High power load
Table of Contents

Advertisement

20 PRODIGIT
3-2

STORE / RECALL operation

The six function keys on the front panel of 3260A Series High Power Load are designed for
high testing throughput purpose. There are five operation states or testing steps can be store
in the non-volatile memory of 3260A series electronic load, each state can save or recall the
load status and level for four 3260A series Electronic load simultaneously.
3.2.1
STORE procedure:
3.2.1.1
3.2.1.2
3.2.1.3
Note:
1. After press the STORE key, the STORE LED annunciator will flash for 10
2. After press the STORE key, then press the STORE key, then press the STORE
3. After press the STORE key, it is available and useful to operate the front panel
3.2.2
STORE function:
It can store up to states of 3260A series load setting simultaneously, if you store 2
different states in the same state key, the later state will overcome the previous state,
it acts as update the new data.
3.2.3
RECALL operation:
Press one of the state 1 through 5 key, the appropriate LED annunciator will be lit,
the store state on the 3260A Series High Power Load is sending to control unit
simultaneously. Before press the states key, you press any key on the front panel
then the state LED annunciator is blank immediately, it indicates the STORE state
has been changed by read judgement on front panel.
Set the load status and load level from load module respectively.
Press the STORE key on the 3260A front panel, the STORE LED
annunciator is flashing. (about two times every second)
Press one of the state 1-5 key, the appropriate state key's LED annunciator
will be lit immediately, the load level and status of 3260A series load
module is stored into the non-volatile memory this time. The STORE LED
annunciator turns to OFF, it means the STORE procedure is completed.
seconds, if the STATE 1-5 key is not pressed within this 10 seconds, the STORE
LED annunciator will be OFF, it indicated the STORE process is not available now,
please repeat the STORE procedure for a new STORE operation.
LED annunciator will be blank, it indicate the STORE process is not available.
key on the 3260A series Electronic load However, the STATE LED will be OFF if
any key on front panel is operated, this indicates the front panel state of 3260A
series is not the same as STORE state.