Figure 6 Driver Connections
ACTIVE
SPEAKER CABLE
MODULE
PNK
BLK
---
1
WHT/BRN
---
BRN
---
2
WHT/RED
---
RED
---
3
WHT/ORG
---
ORG
---
4
WHT/YEL
---
YEL
---
5
WHT/GRN
---
GRN
---
6
WHT/BLU
---
BLU
---
7
WHT/VIO
---
VIO
---
8
WHT/GRY
---
GRY
RED/WHT
RED/BLK
For the standard cable length supplied with the siren see Table 13. The number of
conductors and colors vary from module to module. For example, in a MOD5020B, there
are 16 wires with only 10 of those being used for driver connections. Note that each cable
has four spare wires used for top or side light connections.
Table 13 Number of Wires and Cable Length per Module
Module
MOD1004B/MOD1004BC
MOD2008B/MOD2008BC
MOD3012B/MOD3012BC
MOD4016B/MOD4016BC
MOD5020B/MOD5020B
MOD6024B/MOD6024BC
MOD8032B/MOD8032BC
MOD6032B/MOD6032BC
Description, Specifications, Installation, and Service Manual
DRIVER -
JUMPER
DRIVER -
TERMINAL
WIRE
TERMINAL
---
---
---
---
---
---
A1 - 2
WHT
A2 - 1
A2 - 2
WHT/BRN
A3 - 2
A3 - 1
WHT
A4 - 2
A4 - 1
BRN
A1 - 1
B1 - 2
WHT
B2 - 1
B2 - 2
WHT/RED
B3 - 2
B3 - 1
WHT
B4 - 2
B4 - 1
RED
B1 - 1
C1 - 2
WHT
C2 - 1
C2 - 2
WHT/ORG
C3 - 2
C3 - 1
WHT
C4 - 2
C4 - 1
ORG
C1 - 1
D1 - 2
WHT
D2 - 1
D2 - 2
WHT/YEL
D3 - 2
D3 - 1
WHT
D4 - 2
D4 - 1
YEL
D1 - 1
E1 - 2
WHT
E2 - 1
E2 - 2
WHT/GRN
E3 - 2
E3 - 1
WHT
E4 - 2
E4 - 1
GRN
E1 - 1
F1 - 2
WHT
F2 - 1
F2 - 2
WHT/BLU
F3 - 2
F3 - 1
WHT
F4 - 2
F4 - 1
BLU
F1 - 1
G1 - 2
WHT
G2 - 1
G2 - 2
WHT/VIO
G3 - 2
G3 - 1
WHT
G4 - 2
G4 - 1
VIO
G1 - 1
H1 - 2
WHT
H2 - 1
H2 - 2
WHT/GRY
H3 - 2
H3 - 1
WHT
H4 - 2
H4 - 1
GRY
H1 - 1
---
---
---
---
---
---
Number of wire and how wires are used
8 wires: 2 are used for driver connections,
4 are reserved for top or side lights
8 wires: 4 are used for driver connections,
4 are reserved for top or side lights
16 wires: 6 are used for driver connections,
4 are reserved for top or side lights
16 wires: 8 are used for driver connections,
4 are reserved for top or side lights
16 wires: 10 are used for driver connections,
4 are reserved for top or side lights
16 wires: 12 are used for driver connections,
4 are reserved for top or side lights
20 wires: 16 are used for driver connections,
4 are reserved for top or side lights
LIGHT
BOTTOM MOUNT +
BOTTOM MOUNT -
---
---
---
---
---
---
---
---
A3
---
---
1 2
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
FIRST ACTIVE MODULE DRIVER ORIENTATION
---
---
---
---
---
---
---
TOP MOUNT +
291347
TOP MOUNT -
Installation
BRN
1
A1
2
WHT JUMP
1 2
A4
1
A2
2
WHT\BRN
TOP VIEW
Cable Length
44 ft
44 ft
42.5 ft
42.5 ft
42.5 ft
42.5 ft
44 ft
19
Need help?
Do you have a question about the Modulator MOD Series and is the answer not in the manual?