Switch

with three positions 1 – 0 –
1
Normal mode. All control functions connected.
0
Heat pump off.
See the section, Actions with operating distur-
bances >Standby mode.
The power switch must not be turned to either the
"1" or "
" position before the heating system
has been filled.

Offset heating curve

The Offset heating curve knob is used to change the
heating curve's parallel offset and in doing so the
room temperature. Turning clockwise increases the
room temperature. When the knob is turned, menu
2.0 is shown on the display and the value for the
calculated flow temperature changes.
Note! Only the knob on the Master unit can be
used for this setting.

Right keypad

The plus button bis used to browse through the
menu system (forwards) or raise the value of the
selected parameter.
See the section Control > General.
The minus button is used to browse through the
menu system (backwards) or lower the value of the
selected parameter.
See the section Control > General.
The enter button is used to select a sub menu in
the menu system, to activate a parameter change as
well as confirm a parameter change.
See the section Control > General.
:
NIBE F1330

Left keypad

The desired operating mode with regard to per-
mitting/blocking of the circulation pump and addi-
tional heating is set using the Operating mode but-
ton. The selection does not need to be confirmed
with the enter button.
The current operating mode is shown on the display
when the button is pressed and the mode changes
when you continue to press the button. The display
returns to the normal display mode once the enter
button is pressed.
The different operating modes are:
Auto mode:
F1330 automatically selects the operating mode by
taking the outdoor temperature into account. The
circulation pumps and additional heating are per-
mitted to be operational when the need arises.
Summer mode:
Only hot water production using F1330. The circu-
lation pumps and additional heating are blocked.
However, when Extra hot water is activated, the ad-
ditional heat (XVV) can be connected.
Spring/Autumn mode:
Only production of heating and hot water us-
ing F1330. The circulation pumps are operational.
Additional heat blocked. However, when Extra hot
water is activated the additional heat (XVV) can be
connected.
Only additional heat:
Compressors blocked. The function can also be acti-
vated/deactivated by pressing the "operating mode
button" for 7 seconds.
Extra hot water
When the button is pressed the current Extra hot
water position is shown on the display, further
pressing changes the position in the increments 24,
12, 6 and 3 hours and off. When Extra hot water is
activated, the hot water temperature is increased to
a higher level (set on menu 1.4) than normal. The
temperature then returns to the normal value. The
function is active when an A is displayed above the
Extra hot water icon.
See screensaver mode.