7.3

Meaning of the Setup Parameters

7.3.1
SCSI Bus Interface Definitions
Host Adapter SCSI
All SCSI devices connected to an SCSI bus, including the SCSI controller,
ID
must have different SCSI addresses.
0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 15
The SCSI controller is set to the displayed SCSI address (default entry: 7)
SCSI Parity
The SCSI controller uses default parity checking on the SCSI bus for
Checking
monitoring data transfer. Older SCSI devices may not support parity
checking. If this is the case, you must disable this option.
Enabled
Disabled
Note
If parity checking is disabled, this applies to all devices connected to the SCSI
bu
Host Adapter SCSI
If the Ultra Wide SCSI controller is the final device on the SCSI cable,
Termination
termination must be enabled. If the Ultra Wide SCSI controller is not the
final device on the SCSI cable, termination must be disabled.
Automatic
LowON/HighON
LowOFF/HighOFF
7.3.2
Additional Options: Boot Device Options
Boot Target ID
The Ultra Wide SCSI controller can start the operating system from a drive
with any SCSI address (ID). The selected SCSI ID must match the one
configured on the drive.
0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 15
The Ultra Wide SCSI controller boots from the drive with the SCSI ID that is
displayed (default setting: 0).
RI 45 PIII, Manual
C79000-G7076-C817-01
Parity checking is activated (default setting)
Parity checking is deactivated.
Host adapter is terminated automatically
Termination is enabled (default setting)
Termination is disabled.
SCSI Option
7-7