ABB RELION 615 Series Applications Manual page 47

Capacitor bank protection and control
Hide thumbs Also See for RELION 615 Series:
Table of Contents

Advertisement

1MRS758955 A
B1
PHIPTOC1_OPERATE
B2
PHHPTOC1_OPERATE
B3
PHHPTOC2_OPERATE
B4
PHLPTOC1_OPERATE
B5
NSPTOC1_OPERATE
B6
NSPTOC2_OPERATE
B1
COLPTOC1_OPR_OVLOD
B2
COLPTOC1_OPR_UN_I
B3
DEFHPDEF1_OPERATE
B4
DEFLPDEF2_OPERATE
B5
DEFLPDEF1_OPERATE
B6
EFHPTOC1_OPERATE
B1
T2PTTR1_OPERATE
B2
SRCPTOC1_OPERATE
B3
CUBPTOC1_OPERATE
B4
NSPTOV1_OPERATE
B5
ROVPTOV1_OPERATE
B6
PSPTUV1_OPERATE
B1
PHPTOV1_OPERATE
B2
PHPTOV2_OPERATE
B3
PHPTUV1_OPERATE
B4
PHPTUV2_OPERATE
B5
B6
B1
ARCSARC1_OPERATE
B2
ARCSARC2_OPERATE
B3
ARCSARC3_OPERATE
B4
B5
B6
GUID-132066E9-99C0-456C-B0BC-EC5B3E42AFC4 V1 EN
Figure 17:
Circuit breaker failure protection function
REV615
Application Manual
The three-phase thermal overload protection T2PTTR1 with two time constants
detects overload under varying load conditions. The BLK_CLOSE output of the
function is used to block the closing operation of circuit breaker.
BLOCK
TEMP_AMB
GUID-39968CD7-297E-451D-BE56-97E126A257D4 V1 EN
Figure 16:
Thermal overcurrent protection function
The circuit breaker failure protection CCBRBRF1 is initiated via the START input by
number of different protection functions available in the protection relay. The circuit
breaker failure protection function offers different operating modes associated with
the circuit breaker position and the measured phase and residual currents.
The circuit breaker failure protection function has two operating outputs: TRRET and
TRBU. The TRRET operate output is used for retripping its own breaker through
TRPPTRC2_TRIP. The TRBU output is used to give a backup trip to the breaker
feeding upstream. For this purpose, the TRBU operate output signal is connected to the
binary output X100:PO2.
OR6
O
O:39|T:2.5|I:7
OR6
O
O:40|T:2.5|I:32
OR6
O
O:41|T:2.5|I:21
OR6
O
O:43|T:2.5|I:12
OR6
O
O:42|T:2.5|I:18
Three arc protection stages ARCSARC1...3 are included as optional functions. The
arc protection offers individual function blocks for three arc sensors that can be
REV615 standard configurations
T2PTTR1
OPERATE
START
ALARM
BLK_CLOSE
OR6
B1
O
B2
B3
B4
B5
B6
O:44|T:2.5|I:41
X110_BI4_CB_CLOSED
Section 3
T2PTTR1_OPERATE
T2PTTR1_START
T2PTTR1_ALARM
T2PTTR1_BLK_CLOSE
CCBRBRF1
BLOCK
CB_FAULT_AL
START
TRBU
POSCLOSE
TRRET
CB_FAULT
O:45|T:2.5|I:1
CCBRBRF1_TRBU
CCBRBRF1_TRRET
41