ABB Relion 630 Series Communication Protocol Manual page 79

Iec 61850 communication protocol
Hide thumbs Also See for Relion 630 Series:
Table of Contents

Advertisement

1MRS756793 E
Table 28:
DSTPDIS Logical node data (instance 10)
DO name
DO type
Beh
a_dINS
Mod
c_dINC
DirRisZn
v2_dMV
DirReactZn
v2_dMV
PhLoopRis1
v2_dMV
PhLoopRea1
v2_dMV
PhLoopRis2
v2_dMV
PhLoopRea2
v2_dMV
Table continues on next page
630 series
Communication Protocol Manual
DA name
FC
stVal
ST
q
ST
t
ST
stVal
ST
q
ST
t
ST
mag.f
MX
q
MX
t
MX
mag.f
MX
q
MX
t
MX
mag.f
MX
q
MX
t
MX
mag.f
MX
q
MX
t
MX
mag.f
MX
q
MX
t
MX
mag.f
MX
q
MX
T
Signal
-
Beh
-
Beh
-
Beh
-
-
-
-
-
-
-
2 DIR_LOOP_R Z3
-
2 DIR_LOOP_R Z3
-
2 DIR_LOOP_R Z3
-
2 DIR_LOOP_X Z3
-
2 DIR_LOOP_X Z3
-
2 DIR_LOOP_X Z3
-
2 FLTLOOP_RFST Z3
-
2 FLTLOOP_RFST Z3
-
2 FLTLOOP_RFST Z3
-
2 FLTLOOP_XFST Z3
-
2 FLTLOOP_XFST Z3
-
2 FLTLOOP_XFST Z3
-
2 FLTLOOP_RSND Z3
-
2 FLTLOOP_RSND Z3
-
2 FLTLOOP_RSND Z3
-
2 FLTLOOP_XSND Z3
-
2 FLTLOOP_XSND Z3
Section 7
Logical node data model
Mon/C
Description
md
Mon
Behaviour parameter for 61850
Mon
Quality: Behaviour parameter for
61850
Mon
Timestamp: Behaviour parameter
for 61850
Mon
Mode status parameter for 61850
Mon
Quality: Mode status parameter for
61850
Mon
Timestamp: Mode status
parameter for 61850
Mon
Record data of bank 2 for direction
resistance, Zone Z3
Mon
Quality: Record data of bank 2 for
direction resistance, Zone Z3
Mon
Timestamp: Record data of bank 2
for direction resistance, Zone Z3
Mon
Record data of bank 2 for direction
reactance, Zone Z3
Mon
Quality: Record data of bank 2 for
direction reactance, Zone Z3
Mon
Timestamp: Record data of bank 2
for direction reactance, Zone Z3
Mon
Record data of bank 2 for PE-loop
resistance (1st), Zone Z3
Mon
Quality: Record data of bank 2 for
PE-loop resistance (1st), Zone Z3
Mon
Timestamp: Record data of bank 2
for PE-loop resistance (1st), Zone
Z3
Mon
Record data of bank 2 for PE-loop
reactance (1st), Zone Z3
Mon
Quality: Record data of bank 2 for
PE-loop reactance (1st), Zone Z3
Mon
Timestamp: Record data of bank 2
for PE-loop reactance (1st), Zone
Z3
Mon
Record data of bank 2 for PE-loop
resistance (2nd), Zone Z3
Mon
Quality: Record data of bank 2 for
PE-loop resistance (2nd), Zone Z3
Mon
Timestamp: Record data of bank 2
for PE-loop resistance (2nd), Zone
Z3
Mon
Record data of bank 2 for PE-loop
reactance (2nd), Zone Z3
Mon
Quality: Record data of bank 2 for
PE-loop reactance (2nd), Zone Z3
73