ABB Relion 630 Series Communication Protocol Manual page 67

Iec 61850 communication protocol
Hide thumbs Also See for Relion 630 Series:
Table of Contents

Advertisement

1MRS756793 E
Table 19:
DSTPDIS Logical node data (instance 1)
DO name
DO type
Beh
a_dINS
Mod
c_dINC
DirRisZn
v2_dMV
DirReactZn
v2_dMV
PhLoopRis1
v2_dMV
PhLoopRea1
v2_dMV
PhLoopRis2
v2_dMV
PhLoopRea2
v2_dMV
Table continues on next page
630 series
Communication Protocol Manual
DA name
FC
stVal
ST
q
ST
t
ST
stVal
ST
q
ST
t
ST
mag.f
MX
q
MX
t
MX
mag.f
MX
q
MX
t
MX
mag.f
MX
q
MX
t
MX
mag.f
MX
q
MX
t
MX
mag.f
MX
q
MX
t
MX
mag.f
MX
q
MX
T
Signal
-
Beh
-
Beh
-
Beh
-
-
-
-
-
-
-
1 DIR_LOOP_R Z1
-
1 DIR_LOOP_R Z1
-
1 DIR_LOOP_R Z1
-
1 DIR_LOOP_X Z1
-
1 DIR_LOOP_X Z1
-
1 DIR_LOOP_X Z1
-
1 FLTLOOP_RFST Z1
-
1 FLTLOOP_RFST Z1
-
1 FLTLOOP_RFST Z1
-
1 FLTLOOP_XFST Z1
-
1 FLTLOOP_XFST Z1
-
1 FLTLOOP_XFST Z1
-
1 FLTLOOP_RSND Z1
-
1 FLTLOOP_RSND Z1
-
1 FLTLOOP_RSND Z1
-
1 FLTLOOP_XSND Z1
-
1 FLTLOOP_XSND Z1
Section 7
Logical node data model
Mon/C
Description
md
Mon
Behaviour parameter for 61850
Mon
Quality: Behaviour parameter for
61850
Mon
Timestamp: Behaviour parameter
for 61850
Mon
Mode status parameter for 61850
Mon
Quality: Mode status parameter for
61850
Mon
Timestamp: Mode status
parameter for 61850
Mon
Record data of bank 1 for direction
resistance, Zone Z1
Mon
Quality: Record data of bank 1 for
direction resistance, Zone Z1
Mon
Timestamp: Record data of bank 1
for direction resistance, Zone Z1
Mon
Record data of bank 1 for direction
reactance, Zone Z1
Mon
Quality: Record data of bank 1 for
direction reactance, Zone Z1
Mon
Timestamp: Record data of bank 1
for direction reactance, Zone Z1
Mon
Record data of bank 1 for PE-loop
resistance (1st), Zone Z1
Mon
Quality: Record data of bank 1 for
PE-loop resistance (1st), Zone Z1
Mon
Timestamp: Record data of bank 1
for PE-loop resistance (1st), Zone
Z1
Mon
Record data of bank 1 for PE-loop
reactance (1st), Zone Z1
Mon
Quality: Record data of bank 1 for
PE-loop reactance (1st), Zone Z1
Mon
Timestamp: Record data of bank 1
for PE-loop reactance (1st), Zone
Z1
Mon
Record data of bank 1 for PE-loop
resistance (2nd), Zone Z1
Mon
Quality: Record data of bank 1 for
PE-loop resistance (2nd), Zone Z1
Mon
Timestamp: Record data of bank 1
for PE-loop resistance (2nd), Zone
Z1
Mon
Record data of bank 1 for PE-loop
reactance (2nd), Zone Z1
Mon
Quality: Record data of bank 1 for
PE-loop reactance (2nd), Zone Z1
61

Advertisement

Table of Contents
loading

Table of Contents