6. Software

6.1. IP address configuration

The IP address is usually issued via DHCP. The device is supplied with DHCP activated. Should the
alarm control unit not receive an address using this method, an auto IP (address range from
169.254.1.0 to 169.254.254.255) is issued after a certain waiting time.
You can also issue a static IP address via the ETS or the Gira Project Assistant. You can set IP address,
IP subnet mask and IP standard gateway here.
Notes
• The IP address configuration will only be adopted if the alarm control unit Connect is disarmed and
the housing cover is open!
Important: When you open the housing cover, a tamper alarm triggers.
• Recommendation: Change the IP address in the GPA.
IP address configuration in ETS 5
Order No. 5201 00
Software
Page 21