INSTALLATION AND WIRING
Assembly
1
Connections
L:
data & audio.
+, -: power supply (18 Vdc).
V: live (coaxial - video).
M: shield (coaxial - video).
Ct: camera activation (10 Vdc).
F1
F2
M
V
V
M
+
-
L
CT
A
T
L
-
F1
F2
M
V
V
M
+
-
L
CT
A
T
L
-
1 2
4
2
T, -:
A, +: extension Call connection ref. 2040,...
F1, F2:Additional functions (negative output).
Maximum current per pussbutton F1, F2: 50mA with
F1
F2
P1
M
V
V
M
+
-
L
CT
A
T
M V
+
F1
F2
M
V
V
M
P1
+
-
L
CT
A
T
+
Disassembly
call pushbutton at the apartment's door (P1).
L
-
P1
L +
-
-
P1
L
L +
-
1
90º
DISTRIBUIDOR VIDEO 2 SALIDAS
REF.2448
2 OUTPUTS VIDEO DISTRIBUTOR
+
R
1
5
(-)
4
3
V
M
V
M
+18
V
R1
+
M
75
M
V
DISTRIBUIDOR VIDEO 2 SALIDAS
REF.2448
2 OUTPUTS VIDEO DISTRIBUTOR
+
+
R
1
5
(-)
V
M
V
M
4
3
+18
R1
75
2
12Vdc.
2
6
V
M
V
M
2
6
V
M
V
M