2.4 INSTALLING PERMANENT WIRING

If permanent wiring is required by local codes, the follow-
ing procedure must be performed.
WARNING
DISCONNECT FREEZER FROM THE SOURCE
OF ELECTRICAL SUPPLY BEFORE SERVICING.
A. Remove the left side panel and electrical box cover.
B. Disconnect the wires from the terminal
block. Disconnect the green ground wire from the
grounding stud. (Fig. 8).
Figure 8. Power Cord Connection
C. Remove the power cord.
D. Install permanent wiring according to local code.
E. Replace the electrical box cover and left side panel.