Macurco AimSafety PM 100 User Instructions

Bump test & calibration station
Hide thumbs Also See for AimSafety PM 100:

Advertisement

Quick Links

AimSafety™ PM
Bump Test & Calibration
100
R
R
Station
Bump Test and Calibration Station for PM
100
R
User Instructions
IMPORTANT: Keep these user instructions for reference.

Advertisement

Table of Contents
loading

Summary of Contents for Macurco AimSafety PM 100

  • Page 1 AimSafety™ PM Bump Test & Calibration Station Bump Test and Calibration Station for PM User Instructions IMPORTANT: Keep these user instructions for reference.
  • Page 3: Table Of Contents

    PM100 Bump Test and Calibration Station General Safety Information ............................3 List of warnings ..............................3 Use Instructions and Limitations ..........................4 Use For ................................4 Features ................................5 Specifications ..............................5 Operation.................................. 6 Power ................................6 LEDs .................................. 6 Charge Battery ..............................
  • Page 4: General Safety Information

    PM100 Bump Test and Calibration Station 1 General Safety Information 1.1 List of warnings WARNING Each person using this equipment must read and understand the information in this user manual before use. Use of this equipment by untrained or unqualified persons or use that is not in accordance with this user manual, may adversely affect product performance.
  • Page 5: Use Instructions And Limitations

    PM100 Bump Test and Calibration Station 2 Use Instructions and Limitations 2.1 Use For The AimSafety Bump/Calibration Station for PM is an all-in-one testing/calibration station for PM portable gas monitors. The Bump-Calibration Station utilizes the IR communication of the PM Monitors to perform testing and calibration by pressing only a single button.
  • Page 6: Features

    PM100 Bump Test and Calibration Station 2.2 Features Simultaneously test four PM gas monitors • • Rechargeable internal battery lasts up to 1000 bump tests on a single charge Internal gas cylinder regulator and pressure gauge • • USB flash drive for bump test and event log storage •...
  • Page 7: Operation

    PM100 Bump Test and Calibration Station 3 Operation The Bump-Calibration Station is operated using only two buttons. 3.1 Power To turn on the power, 1. Press either the Bump Test or the Calibration button for one second. 2. The Power LED will initially turn on to orange, then switch to green when the unit is ready. If the unit has a low battery, the power LED will switch to red.
  • Page 8: Exhaust Port

    PM100 Bump Test and Calibration Station The Gas Expiration date and Gas Bottle Lot # can be recorded using the Bump-Calibration Station Manager software (See Section 5.3.1.1 Station Info). 3.5 Exhaust Port The exhaust port is located on the left side of the unit next to the charging port. During an active test, the test gas will exit the unit through this port.
  • Page 9: Test Troubleshooting

    PM100 Bump Test and Calibration Station The Bump-Calibration Station performs the Span Calibration but does not perform the Zero Calibration. It is recommended to perform a Zero Calibration prior to performing the Span Calibration using the Bump- Calibration Station. A Zero Calibration can be done using the PM monitor interface or with the assistance of the PM Link.
  • Page 10: Download And Installation

    Set time and date 5.1 Download and Installation 5.1.1 Download the software Download the Bump-Calibration Station Manager software from the following link: h ttps://www.macurco.com/?ddownload=2090 3 2 T U U 3 2 T Save the file to a place you will remember.
  • Page 11 PM100 Bump Test and Calibration Station 5. Now select the installation folder. The default folder is the best option for most people. Click Next. 6. The installation is ready to begin. Click Install. 7. You may receive a warning. Click Yes to continue. REV –...
  • Page 12: Connect To The Calibration Station

    PM100 Bump Test and Calibration Station 8. When the installation is complete, click Finish to exit the Setup Wizard. 5.2 Connect to the Calibration Station When the Bump-Calibration Station Manager software is first opened, the fields are grayed out. The software must be connected to the Bump-Calibration Station before it can be used.
  • Page 13: Connect Using Usb Disk

    PM100 Bump Test and Calibration Station 6. Press OPEN in the upper right corner of the software interface. NOTE: If the software is opened before the PM Link device is plugged into the computer, a “Port open fail” message may popup. If this occurs, close the software and reopen it. 7.
  • Page 14: Station Tab

    PM100 Bump Test and Calibration Station 5.3.1 Station Tab The Station tab is displayed when the software opens (as shown above). It shows information about the Bump- Calibration Station, information about the installed gas cylinder, configuration of the operation of the Bump- Calibration Station, and the Bump-Calibration Station firmware upgrade interface.
  • Page 15 PM100 Bump Test and Calibration Station Docking Time Auto Sync – If checked, the time on the Bump-Calibration Station will be synced to the computer time. If unchecked, the time can be manually adjusted within the Time tab. Location A custom location can be added up to 12 alphanumeric characters. This can be useful to keep data from multiple Bump-Calibration Stations organized.
  • Page 16: Pm100 Tab

    PM100 Bump Test and Calibration Station The “Concentration” option will run the bump test until the test gas concentration is verified. If the units are in Stealth Mode, the Concentration option will be required for a successful bump test. The “Beep + Concentration” option will run the bump test until the audible alarm is detected and the test gas concentration is verified.
  • Page 17 PM100 Bump Test and Calibration Station software shows the available configuration options for PM devices. All configuration settings can be set to be simultaneously updated during each bump test or calibration (see Section 5.3.1.2 Enable/Disable Function). 5.3.2.1 PM100 Configuration Options Each configuration option can be enabled/disabled using the checkbox on the left side.
  • Page 18 USB Disk. PM monitors require a firmware file that is specific to the monitor’s gas type. If there is a new firmware version, the file can be found at https://macurco.com/downloads/. To update the PM firmware file, 1.
  • Page 19: Logs Tab

    PM100 Bump Test and Calibration Station 5.3.3 Logs Tab Logs are stored on the USB Disk and can be viewed on a computer using the Bump-Calibration Station Manager software. The log files will be formatted as .csv files (comma separated values) for easy viewing and manipulation with spreadsheet software.
  • Page 20 PM100 Bump Test and Calibration Station 5.3.3.2 Save Logs to Computer The log files can be saved to the computer. To save the log files to the computer, 1. Select the desired log files to save. Click the Select All check box to select or deselect all log files at once. Individual log files can be selected by clicking on their respective check box.
  • Page 21: Time Tab

    PM100 Bump Test and Calibration Station 5.3.4 Time Tab The Bump-Calibration Station adds time data to all its logs. If the Bump-Calibration Station time is incorrect, it can easily be updated to the correct time using the Bump-Calibration Station Manager software. The time can only be set when connected using the PM Link.
  • Page 22: Aimsafety Product Limited Warranty

    OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE ARE LIMITED TO A PERIOD OF TWO (2) YEARS FROM THE PURCHASE DATE. Macurco shall not be liable for any incidental or consequential damages for breach of this or any other warranty, express or implied, arising out of or related to the use of said gas detector. The manufacturer or its agent’s liability shall be limited to replacement or repair as set forth above.