Ferroli BLUEHELIX B 32 K 50 Use, Installation And Maintenance Instructions
Ferroli BLUEHELIX B 32 K 50 Use, Installation And Maintenance Instructions

Ferroli BLUEHELIX B 32 K 50 Use, Installation And Maintenance Instructions

Hide thumbs Also See for BLUEHELIX B 32 K 50:

Advertisement

Quick Links

BLUEHELIX B 32 K 50
IT ISTRUZIONE PER L'USO L'INSTALLAZIONE E LA MANUTENZIONE
ES INSTRUCCIONES DE USO, INSTALACIÓN Y MANTENIMIENTO
TR KULLANMA, KURULUM VE BAK M TALIMATLAR
EN INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE
FR INSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D'ENTRETIEN
,
RU
U
,

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BLUEHELIX B 32 K 50 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ferroli BLUEHELIX B 32 K 50

  • Page 1 BLUEHELIX B 32 K 50 IT ISTRUZIONE PER L’USO L'INSTALLAZIONE E LA MANUTENZIONE ES INSTRUCCIONES DE USO, INSTALACIÓN Y MANTENIMIENTO TR KULLANMA, KURULUM VE BAK M TALIMATLAR EN INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE FR INSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D'ENTRETIEN...
  • Page 2: General Warnings

    2 Domestic hot water (DHW) “d1“ 2. OPERATING INSTRUCTIONS fig. 3 2.1 Introduction Fault BLUEHELIX B 32 K 50 sealed chamber, premix "d3" "d4" condensing heat exchanger in steel 2.3 Connection to the power supply, switching on and off...
  • Page 3 Switching the boiler off and on Room temperature adjustment (with optional room thermostat) Press the on/off button (detail 7 - fig. 1) for 5 seconds. Using the room thermostat, set the temperature required in the rooms. If the room ther- mostat is not installed, the boiler will keep the system at the set system delivery setpoint temperature.
  • Page 4: Installation

    System water pressure adjustment 7 Gas inlet - 1/2” 10 System delivery - 3/4” The filling pressure read on the boiler water gauge with the system cold must be approx 1.0 bar. If the system pressure falls to values below minimum, the boiler stops and fault 8 DHW outlet - 1/2”...
  • Page 5: Air Inlet

    3.6 Fume ducts Table. 4 - Typology Important Type Description The unit is a “C type” with sealed chamber and forced draught; the air inlet and fume out- Wall horizontal exhaust and intake. The inlet/outlet terminals must be concentric or close enough to be let must be connected to one of the following extraction/suction systems.
  • Page 6 Configuration of flues Air inlet = / Fume outlet = Table. 7 - Connection with coaxial pipes Left outlets 041001X0 Rear outlets 041001X0 Right outlets 1KWMA64W 041001X0...
  • Page 7 Table. 8 - Connection with separate pipes Left outlets Rear outlets Right outlets...
  • Page 8: Service And Maintenance

    70 (for operation with LPG). If the boiler is to be connected BLUEHELIX B 32 K 50 to a collective flue or a single flue with natural draught, the flue or chimney must be expressly designed by professionally 11.
  • Page 9 TEST mode activation Press the heating buttons (details 3 and 4 - fig. 1) together for 5 seconds to activate the TEST mode. The boiler lights at the maximum heating power set as described in the fol- lowing section. The heating and DHW symbols (fig. 23) flash on the display; the heating power will ap- pear alongside.
  • Page 10: Technical Data And Characteristics

    4.4 Troubleshooting Fault code Fault Possible cause Cure Diagnostics Heating sensor fault Sensor damaged Replace the sensor In case of operation faults or problems, the display flashes and the fault identification No system H O circulation Check the circulating pump Exchanger protection code appears.
  • Page 11 5.1 General view and main components 50 50 50 60 50 fig. 27 - Rear view fig. 25 - Front view fig. 28 - Top view (AIR INLET = / FUME OUTLET = fig. 26 - Side view...
  • Page 12: Water Circuit

    DHW flow rate t 30°C l/10min DHW flow rate t 30°C fig. 30 - Circulating pump head / Pressure losses BLUEHELIX B 32 K 50 Protection rating A = Boiler pressure losses - B = Circulating pump min. speed - C = Circulating pump...
  • Page 14 5.5 Wiring diagram LC32 FUSE 3.15A 250V 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 13 14 15 16 17 18 19 20 21 22 23 24 7 8 9 10 11 12 10 11 12 13 14 15 16 17 18 186 44...