Noraxon Ultium Linear Force SmartLead User Manual

Biomechanics research system
Table of Contents

Advertisement

Quick Links

Linear Force SmartLead
Ultium
Biomechanics
Research System
Ultium Linear Force
SmartLead
User Manual
P-802 Rev B (May 2019)
i

Advertisement

Table of Contents
loading

Summary of Contents for Noraxon Ultium Linear Force SmartLead

  • Page 1 Linear Force SmartLead Ultium Biomechanics ™ Research System  Ultium Linear Force SmartLead User Manual P-802 Rev B (May 2019)
  • Page 2 Noraxon and myoRESEARCH are registered trademarks and the Noraxon logo, myoANALOG, myoFORCE, myoMETRICS, myoMOTION, myoMUSCLE, myoPRESSURE, myoVIDEO, myoSYNC, NiNOX, TRUsync and Ultium are common-law trademarks of Noraxon U.S.A., Inc. All other trademarks are the property of their respective owners. ©2018, all rights reserved.
  • Page 3: Table Of Contents

    Linear Force SmartLead Table of Contents 1 Introduction ........................... 1 1.1 Brief Description ........................1 1.2 Contraindications ........................1 2 Definitions ............................. 1 2.1 Graphic Symbols and Meaning ....................1 2.2 Glossary of Terms ........................2 3 Identification ..........................3 3.1 Model Designation .........................
  • Page 4 15 Specifications of the Product ....................19 15.1 Expected Useful Lifetime ....................19 15.2 Technical Specifications ....................19 Environmental Conditions for Storage and Transport..............19 16 Technical Information ....................... 19 Part 820/821 Linear Force (Ultium Linear Force SmartLead SmartLead) ......19 P-802 Rev B (May 2019)
  • Page 5: Introduction

    2 Definitions 2.1 Graphic Symbols and Meaning The following international icons and symbols may be found on the Ultium Linear Force SmartLead enclosures and in this user manual. Their meaning is described below. Read material in the Instruction Manual wherever this symbol appears.
  • Page 6: Glossary Of Terms

    Linear Force SmartLead 2.2 Glossary of Terms Ultium Sensor -- A small individual radio transmitter typically worn on the body used to measure and transmit bio-potential signals (such as EMG) or motion related signals (such as acceleration). The Ultium Systems can accommodate up to 16 body worn Ultium Sensors in one network. Two Ultium Systems may be used in parallel, on separate RF networks, to accommodate up to 32 body worn sensors.
  • Page 7: Identification

    Ultium Linear Force SmartLead, 500 lbF (Part #820) or 100 lbF (Part #821) 3.2 Product Versions and Configurations The model 820/821 Ultium Linear Force SmartLead must be utilized in conjunction with the Ultium EMG Sensor (Part# 810) and the Ultium Receiver (Part #880).
  • Page 8: General Warnings And Cautions

    4.2 Safety Information Summary Cautions • Never use the Ultium Linear Force SmartLead to collect data from a person with an implanted pacemaker • Never operate the Ultium Linear Force SmartLead within 1 meter of any critical medical...
  • Page 9: Getting Started

    Linear Force SmartLead 5 Getting Started 5.1 Quick Start Guides Please see the hardware manual for the appropriate EMG system. P-880: Ultium user manual P-802 Rev B (May 2019)
  • Page 10: Preparing The Product For Use

    SML Load Cell (Part #SML-500 or #SML-100) Additional contents not illustrated Ultium Linear Force SmartLead User Manual (part #820/821A) This document If additional accessories have been included please see Section 9, Accessories for component identification. 6.2 Component Inputs, Outputs and Indicators 1) EMG Sensor (front and top edge) Smart Lead Connector –...
  • Page 11: Component Interconnections

    Linear Force SmartLead Status LED – Sensor operational indicator flashes green when measuring. Solid Yellow when charging. Power Button – Power the sensor On/Off. Hold for 3+ seconds for a hard reset. 2) EMG Sensor (back and bottom edge) Charger Contacts – Sensor battery is charged and sensor data is exchanged through these points.
  • Page 12: Device Communication (Driver) Software Installation

    Linear Force SmartLead Step 2 Connect the Linear Force SmartLead to the Ultium EMG sensor. 6.4 Device Communication (Driver) Software Installation No driver installation is needed. The Ultium Receiver communicates over the USB port. P-802 Rev B (May 2019)
  • Page 13: Companion Software Installation

    Refer to the Ultium system’s hardware manual for instructions for the program (MR3 myoMUSCLE) supplied with the Noraxon system. For specific settings for the Ultium Linear Force SmartLead see below:...
  • Page 14: Mr3 Configuration

    Linear Force SmartLead 6.6.1 MR3 Configuration Step 1 Enter the Hardware Setup screen and setup the Noraxon EMG system in accordance with its provided hardware manual. Step 2 Click ‘Detect Sensors in Charger’ (All sensors which you would like to use must be in the charger) –...
  • Page 15 Linear Force SmartLead Step 3 Once back in the Home screen, choose to create a new or edit an existing configuration. Step 4 In the measurement setup screen, insert the Ultium system into the Devices in your configuration box. It is recommended that you redetect sensors in the hardware configuration every time the SmartLeads are removed from the Ultium sensor (redetection is necessary to revert to the use of the sensor’s EMG functionality).
  • Page 16: Find My Sensor Feature

    Footswitch channel to be recorded. Step 5b Continue with the measurement setup as described in the Noraxon system’s hardware manual. 6.6.2 Find My Sensor Feature Allows the user to quickly locate a specified Ultium sensor while creating/editing a MR3 configuration (refer to section 7 for guidance on how to create or edit a configuration). If one of the stars (refer to the figure below) is clicked, the corresponding sensor will repeatedly blink light purple in bursts of 3.
  • Page 17: Pre-Use Check-Out

    STATUS LED will flash recognizably faster (green). Quick Testing: To ensure that the Ultium Linear Force SmartLead is measuring properly when connected to the Ultium Sensor and attach a known weight to the Linear Force sensor. Verify that the signal shows the same force as the known force.
  • Page 18: Operating Instructions

    Never use the Noraxon Ultium System on a person with an implanted pacemaker • Never operate the Noraxon Ultium System within 1 meter of any critical medical device 8.2 Normal Functions with Interface to a PC When used with the companion software the Linear Force SmartLead will display and record a signal in lbf.
  • Page 19: Accessories And Optional Modules

    Linear Force SmartLead • Position all components inside the system travelling case according to their prepared cavities. (see photo below) 9 Accessories and Optional Modules 9.1 Accessories The Linear Force SmartLead does not have any corresponding accessories. 10 Cleaning 10.1 Safety Precautions When Cleaning WARNING Only use a damp cloth with mild soap and water or isopropyl alcohol to clean the bottom of the Ultium Sensors.
  • Page 20: Maintenance

    11.3 Companion Software Updates • Perform a backup of the data folders to a separate drive as a precaution. • Click on the Patch/Update link provided in the email or as given on the Noraxon website. • Download the Patch/Update file. •...
  • Page 21: Trouble Shooting, Fault Diagnosis

    Receiver System. 13.2 Warranty Information Noraxon equipment including optional items is guaranteed to be free from defects in material and workmanship for 1 year from the date of purchase. The warrant period begins on the date of product shipment from Scottsdale, Arizona.
  • Page 22: Submitting Technical Support Requests

    If you are shipping from outside the USA please use UPS, FedEx, DHL, or EMS (US Postal Service) and not a freight-forwarder. Using a freight-forwarder incurs additional brokerage fees. If a package is shipped to Noraxon via a carrier other than the ones listed above, it may be refused. 14 Spare Parts and Consumables Consumable Items There are not any consumable items for this product.
  • Page 23: Specifications Of The Product

    16 Technical Information Part 820/821 Linear Force (Ultium Linear Force SmartLead SmartLead) Each Ultium Linear Force SmartLead (part # 820/821) works in-line with an Ultium EMG sensor (part #810.) Each SmartLead is identified by a unique serial number. P-802 Rev B (May 2019)