  • Page 2 Thank you for choosing a DOMUSA TEKNIK heating boiler. From the range of DOMUSA TEKNIK products you have chosen the Lignum NG model. With a suitable hydraulic installation and with firewood for fuel, this high- efficiency wood boiler will provide the ideal level of comfort for your home.
  • Page 3: Table Of Contents

    CONTENTS Page 1 LIST OF COMPONENTS ..............................2   2 CONTROL COMPONENTS ..............................3   3 INSTALLATION INSTRUCTIONS ............................. 4   3.1 L ......................................4  OCATION 3.2 H .................................. 4  YDRAULIC INSTALLATION 3.3 F ............................... 5  PREPARING THE FIREWOOD 3.4 I ..........................
  • Page 4: List Of Components

    Lignum NG 1 LIST OF COMPONENTS 9. Heat exchanger 1. Water inlet/outlet 10. Wood housing 2. Top cover 11. Peep-hole 3. Safety heat exchanger 12. Base 4. Pipe cleaning mechanism 13. Top door 5. Fume pipes 14. Bottom door 6. Top refractory element 15.
  • Page 5: Control Components

    2 CONTROL COMPONENTS 1. Button for changing Menu settings: 4. Main switch: Used for selecting the adjustable Menu settings. Turn on the controller. 2. STOP button (and reduce value): 5. Fuse carrier: Used to stop the fan and, as a result, the It protects the controller and the elements combustion adjustment.
  • Page 6: Installation Instructions

    - It is obligatory and essential to install the temperature relief valve supplied with the boiler. To correctly install the boiler, carefully follow the instructions given in the section "Installing the temperature relief valve" . If this requirement is not complied with, DOMUSA TEKNIK's guarantee of the appliance will automatically be null and void.
  • Page 7: Fuel: Preparing The Firewood

    Firewood is the fuel which must be used for the Lignum NG boiler. If this requirement is not complied with, DOMUSA TEKNIK's guarantee of the appliance will automatically be null and void. The quality of the fuel plays an important part in the performance and useful life of the boiler. The firewood must have less than 20% water content (humidity).
  • Page 8 Lignum NG Make sure the logs in the fuel loading compartment do not get stuck (avoid logs which are too long). If the logs are too long, they do not fall properly and can cause gaps, causing a drop in the boiler power.
  • Page 9: Ignition And Positioning Of The Firewood

    3.4 Ignition and positioning of the firewood How the firewood is loaded into the housing is very important for an optimised combustion process. It is recommended that the firewood be inserted into the loading compartment as follows: Insert thick pieces of wood or stumps in the top area only 4th Layer: Medium firewood - Load the necessary amount in the compartment...
  • Page 10: Sawn Wood (Planks)

    Lignum NG - Once the fire has spread and embers have formed, distribute them evenly, add the rest of the load on top and fully close the doors. - The control automatically regulates the combustion process. 3.4.3 Sawn wood (planks) Sawn wood can be used in a similar way to kindling to ease ignition above the tunnel.
  • Page 11: Electrical Connection

    Otherwise, the condensation may reach the inside of the boiler and cause irreparable damage, which would not be covered by DOMUSA TEKNIK's guarantee. The condensation pipe should lead to a drain outlet, as a large amount of water may be generated.
  • Page 12: Example Of An Installation With A Buffer Tank

    Lignum NG IMPORTANT: Before carrying out any work on the boiler's electrical installation, always ensure it is disconnected from the mains. IMPORTANT: Make sure that none of the mains cables come into contact with a hot surface (e.g. flue). 3.8 Example of an installation with a buffer tank The Lignum NG boiler is equipped with an electronic control that can govern a circuit with buffer tank, with an external circulation kit to prevent condensation in the heat exchanger.
  • Page 13: Example Of An Installation With A Buffer Tank And Dhw Tank

    To control a DHW circuit, connect a DHW sensor from the hot water tank to the boiler (optionally "Electrical Diagram supplied by DOMUSA TEKNIK) and a 3-way diverter valve (see ” The figure below shows an example of a hydraulic diagram for a heating installation with radiators...
  • Page 14: Adjusting The Combustion Air

    Lignum NG 4 ADJUSTING THE COMBUSTION AIR The various stages of combustion (drying, pyrolysis, gasification and combustion) of the Lignum NG wood boiler take place in a controlled manner in different parts of the boiler. The wood dries and decomposes in the loading compartment via the technique known as "inverted draught", generating a combustible gas.
  • Page 15: Temperature Relief Safety Valve

    5 TEMPERATURE RELIEF SAFETY VALVE In order to avoid the temperature inside the boiler reaching damaging levels, this valve opens and lets the mains water supply pass into the interior coil, thereby dispelling the heat in a fully reliable manner. This occurs when, for hydraulic reasons or due to lack of electric current, the boiler cannot dispel the heat it is generating.
  • Page 16: Starting Up The Boiler

    6.1 Prior warnings Repair and maintenance of the boiler must be carried out by a qualified professional, authorised by DOMUSA TEKNIK. For optimum functioning and conservation of the boiler, it should be serviced annually. Carefully read this instruction manual and keep it in a safe, easily-accessible place. DOMUSA TEKNIK will not be liable for any damages caused by failure to follow these instructions.
  • Page 17: Installation Hand Over

    6.4 Installation hand over After the initial start-up, the installation engineer will explain to the user how the boiler works, making any observations they consider relevant. The installer is responsible for clearly explaining to the user the functioning of any control or regulation device forming part of the installation but not supplied with the boiler.
  • Page 18: Digital Display And Selecting Parameters

    Lignum NG 7 DIGITAL DISPLAY AND SELECTING PARAMETERS The Lignum NG boiler is equipped with a digital touch display for viewing and adjusting the different boiler settings. The various parameters displayed on the main screen are described below. The various parameters displayed on the screen are described in the table below. You can browse through the parameters by pressing the "F"...
  • Page 19 Example of installation with buffer If there is a buffer tank and a DHW tank (see tank and DHW tank ), the selected parameter is 02. In order to work with a DHW Electrical Diagram tank, a domestic hot water temperature sensor (see ) and a 3- Electrical Connection way valve must be connected in the "...
  • Page 20: Boiler Maintenance And Cleaning

    Lignum NG 8 BOILER MAINTENANCE AND CLEANING 8.1 Cleaning the boiler 8.1.1 Ashes The ashes must be cleaned out regularly and properly after every 3 or 5 loads of firewood, depending on the type of wood. The ashes accumulate in both the loading compartment and the refractory combustion chamber and in the flue.
  • Page 21: Boiler Maintenance

    8.2 Boiler maintenance: Various maintenance operations should be carried out at different intervals to keep the boiler in perfect working order. The most important aspects to be checked are as follows: Operation Frequency Clean ashes from the loading compartment, combustion chamber and 3-5 loads of flue.
  • Page 22: Safety Warnings

    DOMUSA TEKNIK shall not be liable for any damage caused to people, animals or property as a result of incorrect handling of the ash drawer or the ash itself.
  • Page 23: Shutting Down The Boiler

    9 SHUTTING DOWN THE BOILER To stop the boiler, press the "STOP" button. In shut-down mode, the fan stops working. To shut down boiler operation completely, unplug it from the mains. 9.1 Detection of lack of fuel The controller automatically detects the lack of fuel. When the fuel runs out, the message AL1 appears on the screen.
  • Page 24: Technical Characteristics

    Lignum NG 10 TECHNICAL CHARACTERISTICS Lignum NG Lignum NG Lignum MODEL NG 40 Maximum output power Performance (indirect method) 88,8 89,4 91,2 Fuel load volume CO at maximum power (10% of O mg/m NOx at maximum power (10% of O mg/m Classification (as per EN 303-5) Class 5...
  • Page 25: Diagrams And Measurements

    11 DIAGRAMS AND MEASUREMENTS Lignum NG Lignum NG Lignum NG Lignum NG MODEL Boiler height (A) 1060 1210 1310 Total height (B) 1165 1315 1415 Feeder connection height (C) 1137 1287 1387 Fumes outlet connection (D) 125-130 146-150 Chimney connection height (E) Height of the Safety Heat Exchanger (F) 1125 1225...
  • Page 26: Electrical Diagram

    Lignum NG 12 ELECTRICAL DIAGRAM yellow-green yellow-green yellow-green yellow-green brown 9 10 11 12 13 14 15 16 17 18 19 20 Lamp ecoSTER200 °C T3 T2 T1 blue ecoMAX 200 Mains 230 V~ 230 V~ blue blue L N 1 2 3 4 5 6 7 8 blue brown yellow-green...
  • Page 27: Sensor Values

    13 SENSOR VALUES The table below shows the electrical resistance values for each temperature on the sensors connected to the boiler. To correctly measure these values, the sensors must be electrically disconnected from their corresponding terminal block: DHW/BOILER SENSOR PTC (1 k at 25ºC) Ω...
  • Page 28: Spares List

    Lignum NG 14 SPARES LIST Boiler Code Description Top door Bottom door LIGNUM NG coil Gas flue cleaning system Controller Bottom back part Outside Refractory parts CLIG000163 Air adjustment LIGNUM NG 20/30 CLIG000111 Air adjustment LIGNUM NG 40...
  • Page 29 Top door Code Description LIGNUM NG 20 top door seal CLIG000116 LIGNUM NG 30 top door seal CLIG000117 LIGNUM NG 40 top door seal CLIG000118 LIGNUM NG door hinge CLIG000003 LIGNUM NG door handle assembly CLIG000004 LIGNUM NG Bakelite arm CLIG000005 LIGNUM NG door fixing CLIG000006...
  • Page 30 Lignum NG Bottom door Code Description LIGNUM NG 20 bottom door seal CLIG000126 LIGNUM NG 30/40 bottom door seal CLIG000127 LIGNUM NG peep-hole CLIG000011 LIGNUM NG peep-hole casing CLIG000012 LIGNUM NG rake CLIG000013 LIGNUM NG ash box CLIG000128 LIGNUM NG 20 bottom front door with refractory CLIG000129 LIGNUM NG 30/40 bottom front door with refractory CLIG000130...
  • Page 31 Coil Code Description LIGNUM NG cooling heat exchanger CLIG000016 LIGNUM NG Temperature relief valve CLIG000017 LIGNUM NG Temperature relief valve casing CLIG000019 LIGNUM NG Temperature relief valve seal CLIG000131...
  • Page 32 Lignum NG Gas flue cleaning system Code Description Code Description 4.8 CLIG000032 LIGNUM NG cleaning axle arm CLIG000132 LIGNUM NG 20 turbulator 4.9 CLIG000034 LIGNUM NG cleaning axle support CLIG000133 LIGNUM NG 30 turbulator CLIG000134 LIGNUM NG 40 turbulator 4.11 CLIG000136 LIGNUM NG flue lid 4.2 CLIG000026 LIGNUM NG turbulator axle 4.14 CLIG000137 LIGNUM NG flue lid insulation 4.3 CLIG000135 LIGNUM NG cleaning axle...
  • Page 33 Code Description LIGNUM NG fan RLIG000113 LIGNUM NG fan cover box RLIG000114 LIGNUM NG fan gasket CLIG000046...
  • Page 34 Lignum NG Controller Code Description LIGNUM NG controller CLIG000048 LIGNUM NG safety thermostat CLIG000049 LIGNUM NG fumes sensor CLIG000050 LIGNUM NG boiler sensor CLIG000051 LIGNUM NG DHW sensor CLIG000052 LIGNUM NG controller light CLIG000053 LIGNUM NG controller housing CLIG000138 6.11 LIGNUM NG capacitor CFOV000151 6.12...
  • Page 35 Bottom back part Code Description LIGNUM NG back part CLIG000139 LIGNUM NG back door insulation CLIG000140...
  • Page 36 Lignum NG Outside...
  • Page 37 Code Description LIGNUM NG front roof CLIG000141 LIGNUM NG back roof CLIG000142 LIGNUM NG 20 left side CLIG000143 8.3-a LIGNUM NG 30 left side CLIG000144 LIGNUM NG 40 left side CLIG000145 LIGNUM NG right side CLIG000146 LIGNUM NG right side CLIG000147 LIGNUM NG right side CLIG000148...
  • Page 38 Lignum NG Refractory parts Code Description LIGNUM NG top refractory element CLIG000158 LIGNUM NG top fibre seal CLIG000159 LIGNUM NG middle refractory element CLIG000160 LIGNUM NG bottom fibre seal CLIG000161 LIGNUM NG 20 bottom refractory element CLIG000108 LIGNUM NG 30/40 bottom refractory element CLIG000109 LIGNUM NG primary air duct RLIG000124...
  • Page 39 Anti-condensates Code Description Rear anti-condensates sheet LIGNUM NG 20 RLIG000118 11.1 Rear anti-condensates sheet LIGNUM NG 30 RLIG000121 Rear anti-condensates sheet LIGNUM NG 40 RLIG000115 Front left anti-condensates sheet LIGNUM NG 20 RLIG000119 11.2 Front left anti-condensates sheet LIGNUM NG 30 RLIG000122 Front left anti-condensates sheet LIGNUM NG 40 RLIG000116...
  • Page 40: Alarm Codes

    Lignum NG 15 ALARM CODES The Lignum NG boiler has an electronic control able to detect overheating or lack of fuel in the boiler. When the electronic control detects an operating error, this is indicated by an alarm code on the display.
  • Page 41: Guarantee Conditions

    2 Years for electric and hydraulic elements, pumps, valves, etc. 5 Years for heat exchangers. During the 2-year period following the date of first start-up, DOMUSA TEKNIK will carry out any repairs of original flaws or defects totally free of charge.
  • Page 42 Lignum NG NOTES: ..........................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................
  • Page 43 NOTES: ..........................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................
  • Page 44 FACTORY & OFFICES Apartado 95 Bº San Esteban s/n 20730 AZPEITIA 20737 ERREZIL (Gipuzkoa) Tel: (+34) 943 813 899 www.domusateknik.com reserves the right to make modifications of any kind to its DOMUSA TEKNIK *CDOC001642* product characteristics without prior notice. CDOC001642 10/19...

This manual is also suitable for:

Lignum ng 20Lignum ng 40Lignum ng 30

Table of Contents