INSTALLATION AND OPERATING INSTRUCTIONS DUALTHERM...
Page 2
Thank you for choosing a DOMUSA TEKNIK heating boiler. Within the product range offered by DOMUSA TEKNIK you have chosen DualTherm model. With a suitable hydraulic installation and with a correct fuel, this boiler will provide the ideal level of comfort for your home.
INDEX Page 1 LIST OF COMPONENTS ..............................4 2 CONTROL COMPONENTS ..............................5 3 INSTALLATION INSTRUCTIONS ............................. 6 3.1 L ......................................6 OCATION 3.2 H .................................. 6 YDRAULIC INSTALLATION 3.3 I ........................7 NSTALLING THE TEMPERATURE RELIEF SAFETY VALVE 3.4 I ) ........................
Page 4
DualTherm 15 CALIBRATION MENU ..............................42 15.1 F ..................................43 EED AUGER FILLING 15.2 F ................................44 EED AUGER CALIBRATION 15.3 M .......................... 45 ANUAL SETTING OF FEED AUGER CALIBRATION 15.4 M ............................45 ANUAL ASH CLEANING ACTIVATION 15.5 M ..........................
Page 5
27.5 F ................................. 62 UME TEMPERATURE SENSOR 27.6 D ............................. 62 RAINING THE CONDENSATE WATER 27.7 B ..............................63 OILER WATER CHARACTERISTICS 28 DIAGRAMS AND MEASUREMENTS ......................... 64 29 CONNECTIONS DIAGRAM ............................65 29.1 B ......................................65 OILER 29.2 B ......................................
2 CONTROL COMPONENTS 14. MENU touch button: 17. ON touch button: This button is used to access and browse This button switches on and off the boiler. through the "User Menu". 18. Boiler temperature touch button: 15. Digital display: This button is used to select the boiler set point It is the main boiler functioning display, on temperature.
DualTherm 3 INSTALLATION INSTRUCTIONS The boiler must be installed by authorised personnel in compliance with the applicable laws and regulations. This boiler is suitable for heating water to a temperature below boiling point at atmospheric pressure. It must be connected to a heating installation and/or a domestic hot water distribution network, which must always be compatible with its performance and power.
• It is obligatory and essential to install a device for raising the return temperature up to 65ºC, to prevent any water condensation in the heat exchanger. If this requirement is not complied with, DOMUSA TEKNIK's guarantee of the appliance will automatically be null and void.
DualTherm 3.4 Installing a Sanit hot water tank (Optional) For a correct electrical connection of a Sanit DHW tank with DualTherm boiler, these steps should be followed: - Unplug the boiler from the mains. - Connect a DHW temperature sensor (supplied optionally) to the sensor terminal strip J7 (Sa; Connections Diagram terminals 18 and 19) (see "...
3.5 Feed auger The DualTHerm boiler is equipped with a hopper for pellet storing. NOTE: The screws to fasten the hopper with the boiler are contained in the documentation bag. NOTE: Position the flexible hose in such a way as to allow the feeding of the pellets with the least possible resistance to the burner.
Otherwise, the condensation may reach the inside of the boiler and cause irreparable damage, which would not be covered by DOMUSA TEKNIK’s guarantee. The condensation pipe should lead to a drain outlet, as a large amount of water may be generated.
3.8 BIO hydraulic kit installation Optionally, a BIO hydraulic kit, within the kits range offered by DOMUSA TEKNIK, could be connected to DualTherm boiler. In that way the features of the boiler will be increased. It is imperative and obligatory to install a buffer tank when the heating system has a mixed circuit...
3.9 Installation with a BT Buffer Tank The DualTherm boiler can be installed with a BT Buffer Tank during the installation from the wide range offered by DOMUSA TEKNIK, which may increase the benefits provided by the boiler in the heating service.
Page 15
The temperature of the BT tank is controlled and managed by a temperature sensor (Sbt) immersed in the buffer tank and electrically connected to the boiler. The temperature sensor is optionally supplied by DOMUSA TEKNIK. Heating...
Page 16
The temperature of the BT tank is controlled and managed by a thermostat (Tbt) installed and immersed in the buffer tank and electrically connected to the boiler. The temperature control thermostat is not supplied by DOMUSA TEKNIK but can be purchased at any specialist central heating supplies warehouse.
The DualTherm boiler can be accompanied by a BT-DUO Buffer Tank during the installation from the wide range offered by DOMUSA TEKNIK, which may increase the benefits provided by the boiler in the heating service. This tank has a hot water storage tank inside, thereby adding the provision of DHW in addition to the buffer tank functionality.
Page 18
DualTherm The boiler is supplied with this installation option disabled. To enable it, the electrical resistance (see "Connection Diagram") (Rbt) connected between terminals 20 and 21 of connection strip J7 must be disconnected and replaced with a temperature sensor (supplied as an option by DOMUSA TEKNIK) or a control thermostat installed in the BT buffer tank.
Page 19
For the correct hydraulic and electrical installation of a BT-DUO buffer tank, carefully follow the instructions in the manual supplied with it. Once the hydraulic and electrical connection described above has been completed, to adjust and "Operation with a BT-DUO configure the BT-DUO buffer tank operation, carefully read the section buffer tank"...
The DualTherm boiler must be fuelled with DIN PLUS-certified wood pellets. The DIN PLUS certificate assures that the fuel's moisture levels and calorific value are ideal for optimum boiler functioning performance. If this requirement is not complied, DOMUSA TEKNIK's guarantee will automatically be null and void.
Do not load firewood into the entire combustion chamber. Always leave a space of at least 10 cm to the deflector. Always put at least four logs at a time. It is advisable to add small wooden slats when using large firewood logs and/or with more moisture.
5.1 Prior warnings Repair and maintenance of the boiler must be carried out by a qualified professional, authorised by DOMUSA TEKNIK. For optimum functioning and conservation of the boiler, it should be serviced annually. Carefully read this instruction manual and keep it in a safe, easily-accessible place. DOMUSA TEKNIK will not be liable for any damages caused by failure to follow these instructions.
5.5 Commissioning In order for the guarantee to be valid, the boiler must be commissioned by personnel authorised by DOMUSA TEKNIK. Before beginning the commissioning, the following must be complied with: - The boiler must be plugged in to the mains.
DualTherm 6 DIGITAL DISPLAY DualTherm boiler is equipped with a digital touch display for viewing and adjustment of the different boiler settings. The display has various display areas where different icons and numbers appear to indicate the different status of the boiler. Boiler status: Heating function enabled.
Page 25
Auxiliary icons. Value or setting related to a temperature is shown by the numerical digits. EXT Value or setting related to the outside temperature is shown by the numerical digits. INT Value or setting related to the room temperature are shown by the numerical digits. bar Value or setting related to the boiler water pressure is shown by the numerical digits.
Page 26
DualTherm It is displayed when a value or setting related to DHW recirculation function is shown by the numerical digits. It displays blinking when the DHW recirculation pump is switched on. It is displayed when the feed auger is switched on and it is displayed blinking when it is in manual operation mode.
7 COMBUSTION MODES The DualTherm boiler is an automatic pellet boiler with the option of manually loading the firewood. The firewood load should be carried out in the burning furnace, which has a water-cooled grill. The DualTherm biuler provides great versatility thanks to its different burning mode. Up to 4 Combustion Modes can be selected: Mode 1 (Pellet only).
DualTherm 7.3 Mode 2 (Combined Mode) In this Combustion Mode, the boiler combines operation with pellets and firewood. The boiler automatically lights up the pellet burner when there is a heat demand. If there is a firewood load in the burning furnace, it will automatically light up with the pellet burner. Once the firewood load is fired, the pellet burner turns off.
7.4 Mode 3 (Automatic firewood) In this Combustion Mode, the boiler operates with firewood and uses the pellet exclusively for its automatic firing. When the firewood furnace door is opened and closed, the pellet burner is activated to fire the firewood whenever there is a heat demand.
DualTherm 7.5 Mode 4 (Manual firewood) In this Combustion Mode, the boiler operates exclusively with firewood. The firewood should be fired manually. Once the firewood is consumed, the boiler will remain off until the wood is reloaded. The ignition process is manual and should be performed as follows: Load the burning furnace with firewood.
8.2 Operating with a Sanit DHW tank (Option) DualTherm boiler could be installed together with a DHW tank Sanit, within the product range offered by DOMUSA TEKNIK, to obtain Domestic Hot Water service. Follow the instructions “Installing a Sanit hot water tank”...
DualTherm 8.3 Boiler temperature set point selection Boiler temperature set point selection is made by the tactile selector shown in the picture. Press “+” and “-“ buttons to increase or decrease the set point desired. Few seconds after the desired set point temperature is adjusted the display returns to main position.
8.5 Selecting the set point temperature of the buffer tank (only with buffer tank) The desired buffer tank temperature is selected using the touch button, as shown in the figure. To select the desired temperature, touch the "+" or "-" symbols to increase or decrease the temperature.
DualTherm 9 OPERATING WITH BIO HYDRAULIC KITS (OPTIONAL) All models in the DualTherm boiler line can be connected to a kit of the BIO Hydraulic Kit line to manage more than one heating circuit, always accompanied by a buffer between the boiler and the heating system.
The DualTherm boiler can be accompanied by a BT Buffer tank from the wide range of tanks offered by DOMUSA TEKNIK. This tank accumulates heat energy that improves the performance of the system when switching the boiler on and off. For its correct installation, carefully follow the assembly instructions included with the tank and for its correct integration with the DualTherm "Installing a BT Buffer tank"...
DualTherm 10.2 Operation with a control thermostat in the BT buffer tank (P.08 = 3 or 4) (see In this operating mode you must select the desired set point temperature of the boiler "Selecting the boiler set point temperature") and, using the control thermostat installed in the buffer tank, you must also select the desired set point temperature in the buffer tank.
The DualTherm boiler can be accompanied by a BT-DUO Buffer tank from the wide range of tanks offered by DOMUSA TEKNIK. This tank accumulates heat energy that improves the performance of the system when switching the boiler on and off. It also incorporates a DHW cylinder in its interior for obtaining Domestic Hot Water.
DualTherm 12 OPERATING WITH LAGO FB OT+ REMOTE CONTROL (OPTIONAL) A remote control (LAGO FB OT+) can optionally be supplied together with DualTherm boiler. This remote control can be used to fully operate the boiler from anywhere in the room in which it is installed.
13 USER MENU User Menu " " shows the settings related to boiler functioning on the digital display. To access this menu press MENU; press this button repeatedly to browse through the different settings available. When one of the options is displayed, after 20 seconds the display returns to main "User Menu"...
Page 40
DualTherm Actual boiler water pressure. Actual active boiler temperature set point. Mixing heating circuit nº 1 flow temperature set (18) point setting by means of the tactile button (BIO Hydraulic kit option only) Actual mixing heating circuit nº 1 flow temperature. (BIO Hydraulic kit option only) Mixing heating circuit nº...
14 SETUP MENU "Setup menu" consists of operating parameters of the boiler which can be adjusted by the user (Timer programming, time setting, ...) “Setup menu" To access to the press . Browse through the menu by pressing the symbols "+" or "-" (18) of heating .
DualTherm 14.1 Timers programming process DualTherm boiler allows setting 3 different timers: boiler timer, CVS Suction System timer (if there “Technical is any connected) and DHW recirculation pump timer (if this function is activated on the Menu”) . The default setting for the timers is disabled ("- - - -"), so the functioning that is regulated by each timer will operate 24 hours.
permanently. 14.4 DHW recirculation function timer programming (DHW tank option only) This timer is only displayed when the DHW recirculation function is selected in the multifunction relay parameter (P.20 = 2) of the ”Technical Menu” . It is used to adjust the switching on and off periods of DHW recirculation pump.
DualTherm 15 CALIBRATION MENU "Calibration Menu" consists of a number of processes and parameters that allow the correct set up of the boiler. “Calibration Menu" To access the , the boiler must be switched off by pressing tactile button. After having switched off the boiler press for 5 seconds to access to the menu.
15.1 Feed auger filling During the commissioning of the boiler, before calibrating the feed auger or if the hopper runs out of fuel, it is compulsory to fill of fuel the feed auger. By means of this parameter the feed auger will be filled of fuel, process required for a correct boiler functioning.
DualTherm 15.2 Feed auger calibration By means of calibrating the feed auger the electronic controller of the boiler adjusts the optimum amount of fuel required to supply the burner and to produce the correct heat output and combustion. By means of this parameter the feed auger calibration procedure will be made, process required for a correct boiler functioning.
15.3 Manual setting of feed auger calibration By means of this parameter the weight obtained in the feed auger “Manual setting of calibration procedure can be set manually. When feed auger calibration” "Calibration parameter is displayed ( ) on Menu" , press to access and set the value desired by pressing "+"...
Page 48
DualTherm Nº Parameter Display Access code (by default 1234) P.01 Boiler model P.02 Minimum boiler heat output (%) P.03 Maximum boiler heat output (%) P.04 General fan speed factor (%) P.05 Fuel for ignition (g) P.06 Fuel consumption (kg/h) Selecting the type of installation for the BT buffer P.08 tank (Only with buffer tank installed)
Page 49
Nº Parameter Display Heating circuit n. 2 K-factor curve P.12 (Bio Hydraulic kit option only) P.13 Boiler minimum temperature mode P.14 Minimum boiler temperature (ºC) P.15 Heating pump post-circulation time (min) DHW pump post-circulation time (min) P.16 (DHW tank option only) Legionella protection function P.17 (DHW tank option only)
DualTherm Nº Parameter Display BIO Hydraulic Kit direct pump operating mode P.23 (BIO Hydraulic Kit option only) P.24 Reset default values P.25 Set access code Maximum heating flow temperature of mixed P.27 circuits (Only with the optional Hydraulic Kit Bio) BT buffer tank temperature hysteresis P.28 (Only with buffer tank installed)
17.1 Boiler Model (P.01) Parameter P.01 displays the model of the boiler set at DIP-switch on the electronic board. P.01 = 25 => DualTherm 25 P.01 = 35 => DualTherm 35 17.2 Boiler heat output (P.02, P.03) The DualTherm boiler is configured to modulate the pellet burner power between a minimum and maximum power.
DualTherm 17.6 Managing BT and BT-DUO buffer tanks (P.08, P.28) Parameter P.08 is used to set the type of hydraulic installation that has been used for the BT or BT- DUO buffer tank. This parameter depends on the installation and must be set by the installer once the buffer tank has been assembled.
18 HEATING CIRCUIT'S SETUP PARAMETERS DualTherm is equipped with an electronic controller to manage efficiently the automatic functioning of the boiler. It also has the following additional parameters to regulate the heating circuit connected. They only may be modified by a person with sufficient technical knowledge of the meaning of each “Technical Menu”...
DualTherm 19.1 DHW installation mode (P.09) DualTherm could be set to be connected to a DHW production installation managed by a 3-way DHW diverter valve or by a hot water tank pump. These two operating modes can be selected by means of P.09 parameter: P.09 = 0=>...
20.4 Anti-frost function This function protects the boiler from freezing during cold weather periods. If the boiler temperature drops below 6 ºC, the heating pump will start running until the boiler temperature reaches 8 ºC. If the boiler temperature continues to drop below 4 ºC, the burner will start running, in order to heat the installation.
DualTherm 21 MULTI-FUNCTIONAL RELAY (P.20) DualTherm is equipped with an auxiliary relay output that may be used to select a series of additional functions that increase the boiler performance, features and comfort of the installation. “Technical Menu” "multi- Several operating modes may be set at P.20 parameter of the to define the functional relay"...
DOMUSA TEKNIK shall not be liable for any damage caused to people, animals or property as a result of incorrect handling of the ash drawer or the ash itself.
DualTherm 23 AIR ADJUSTMENT The DualTherm boiler allows the manual adjustment of the secondary air. The aim of secondary air intake is to optimise firewood combustion while reducing emissions and improving boiler performance. By means of the firewood loading door regulator, the secondary air intake flow rate is regulated in the burning furnace.
24 SAFETY LOCK-OUTS The boiler’s electronic controller may activate the following safety lock-outs to stop the boiler functioning in order to prevent serious damages. When any of these lock-outs occur, the boiler will switch off and an alarm code will be displayed on boiler's screen. IMPORTANT: If any of the safety lock-outs described below should occur repeatedly, switch off the boiler and put in contact with the nearest official Technical Assistance Service.
DualTherm 24.3 Low pressure lock-out When this lock-out occurs, “E19” alarm code will appear on the digital display. The burner and the boiler's circulation pumps will switch off, cutting off the heating and water flow to the installation. This lock-out occurs when the pressure of boiler's water drops below the value set at P.19 "Technical menu"...
Various maintenance operations should be carried out at different intervals of time to keep the boiler in perfect working order. The yearly maintenance operations should be carried out by personnel authorised by DOMUSA TEKNIK. 27.1 Frequency of maintenance of the boiler and chimney The most important aspects to be checked are as follows: Nº...
27.3 Cleaning the vents and rear ash drawer The following procedure is recommended for correctly cleaning the vents: NOTE: Clean the rear ash drawer after cleaning the vents.
DualTherm 27.4 Cleaning of the first step of smoke The heat exchanger of the DualTherm boiler has a first step of smoke without automatic cleaning. The cleaning frequency of this step will depend on the type of fuel and amount of fuel used. Here are the steps to follow for access to cleaning.
27.7 Boiler water characteristics In areas with water hardness of over 25-30 ºfH, treated water must be used in the heating installation to avoid any scale deposits on the boiler. It should be noted that even a few millimetres of scale will greatly reduce the boiler’s heat conductivity, causing a major drop in performance. Treated water must be used in the heating circuit in the following cases: - Very large circuits (containing a large amount of water).
DualTherm 31 TECHNICAL DATA MODEL DualTherm 25 Dualtherm 35 Maximum heat output Efficiency at maximum heat output 90.0 90,7 Minimum heat output 10,5 Efficiency at minimum heat output 88,2 90,4 CO at maximum heat output (10% O mg/m OGC (organic gaseous substances) at...
32 CIRCULATION PUMP AND PRESSURE DROP DualTherm boiler can be installed with a circulation pump supplied by DOMUSA TEKNIK. This pump can be a conventional pump or a high efficiency circulation pump. 32.1 High efficiency circulation pump The high efficiency circulation pump allows savings of up to 70 % in energetic consumption in comparison to conventional pumps.
Page 72
DualTherm Min. For the appropriate sizing of the hydraulic installation, as well as the pump operation curves, the pressure loss caused by the boiler should be taken into account. The following graph describes the load loss curves of the boiler: Presure drops DualThe DualThe...
DualTherm 34 ALARM CODES DualTherm boiler is equipped with an electronic controller that performs continuous self-testing to detect any boiler malfunctioning. When it detects a functioning error, this is indicated by an alarm code on the display. The table below shows the list of the alarm codes: CODE ALARM DESCRIPTION E-01...
Page 87
CODE ALARM DESCRIPTION The pressure of water in the installation drops below the minimum pressure set at P.19 parameter of the·” Technical Menu ” (by default 0,5 bar). The boiler will lock out. To unlock it, fill the installation again up to 1 - 1.5 bar. E-19 Low water pressure.
Page 88
DualTherm CODE ALARM DESCRIPTION Underfloor temperature sensor open circuit, E-32 Underfloor temperature sensor is damaged or disconnected. Sr2. Contact your nearest official technical assistance service to Underfloor temperature sensor short- have it replaced. E-33 circuited, Sr2. Outdoor temperature sensor open circuit, E-34 Outdoor temperature sensor is damaged or disconnected.
Page 89
CODE ALARM DESCRIPTION Check the correct operation and connection of the air pressure sensor and that the burner and ash drawer are E-53 Insufficient air depressure with firewood correctly placed in the boiler. If this alarm occurs repeatedly, you should contact the nearest official Technical Assistance Service.
Page 92
HEADQUARTERS & FACTORY Apartado 95 Bº San Esteban s/n 20730 AZPEITIA 20737 RÉGIL (Guipúzcoa) Tel: (+34) 943 813 899 www.domusateknik.com DOMUSA TEKNIK reserves the right to make modifications of any kind to its product *CDOC001597* characteristics without prior notice. CDOC001597 01/19...