Siemens SCALANCE X-200 Series Compact Operating Instructions page 94

Hide thumbs Also See for SCALANCE X-200 Series:
Table of Contents

Advertisement

Available languages

Available languages

Certifications and approvals
6.1 Notes on the CE Mark
Device type
IEC 60068-2-6 vibration
SCALANCE
X201-3P IRT
5 – 9 Hz: 3.5 mm
9 – 500 Hz: 1 g
1 octave/min, 20 sweeps
X200-4P IRT
5 – 9 Hz: 3.5 mm
9 – 500 Hz: 1 g
1 octave/min, 20 sweeps
Note
The interfaces of the X-200 IE switches can be divided into groups each with 4 ports:
 P1 to P4
 P5 to P8
 P9 to P12
 etc.
If only ports of different port groups are used, the device meets the requirements for
Environment B in compliance with IEEE 802.3, Section 33.4.1.1. If ports of the same port
group are used, the requirements for Environment A are met.
94
IEC 60068-2-27 shock
15 g, 11 ms duration
6 shocks per axis
15 g, 11 ms duration
6 shocks per axis
Compact Operating Instructions, 12/2010, A5E00813159-11