Siemens SCALANCE X-200 Series Compact Operating Instructions page 64

Hide thumbs Also See for SCALANCE X-200 Series:
Table of Contents

Advertisement

Available languages

Available languages

Safety instructions
2.1 Important notes on using the device
Replacing components
EXPLOSION HAZARD
SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION
2 OR ZONE 2.
Requirements for the cabinet/enclosure
When used in hazardous environments corresponding to Class I, Division 2 or Class I,
Zone 2, the device must be installed in a cabinet or a suitable enclosure.
General notices on use in hazardous areas according to ATEX
Requirements for the cabinet/enclosure
To comply with EU Directive 94/9 (ATEX95), this enclosure must meet the requirements of
at least IP54 in compliance with EN 60529.
Suitable cables for temperatures in excess of 70 °C
If the cable or conduit entry point exceeds 70 °C or the branching point of conductors
exceeds 80 °C, special precautions must be taken. If the equipment is operated in an air
ambient in excess of 50 °C, only use cables with admitted maximum operating temperature
of at least 80 °C.
Protection against transient voltage surges
Provisions shall be made to prevent the rated voltage from being exceeded by transient
voltage surges of more than 40%. This criterion is fulfilled, if supplies are derived from
SELV (Safety Extra-Low Voltage) only.
64
WARNING
WARNING
WARNING
WARNING
WARNING
Compact Operating Instructions, 12/2010, A5E00813159-11
SCALANCE X-200

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents