Technical data

• Operating voltage:
• Frequency:
• Power consumption:
• Standby min.:
• Switch output:
• Contact:
• Gap:
• Contact material:
• Max switching capacity: 16 A, 250 V~, cos ϕ = 1;
• Min. switching capacity: 10 mA/230 V AC
• Incandescent lamp load: 1000 W (TR 609 top2 S: 2000 W)
• Halogen lamp load:
• Fluorescent lamp load: uncorrected +
230 –240 V~, +10 %/-15 %
50–60 Hz
ca. 0,4 W
ca. 0,4 W
switching of choice of
external wires is permitted
two way switch
(TR 609 top2 S: NO contact)
<3 mm (µ)
AgSnO
2
4 A, 250 V~, cos ϕ = 0,6
100 mA/12 V AC/DC
1000 W (TR 609 top2 S: 2000 W)
series corrected 1000 W
(TR 609 top2 S: 2000 W)
parallel correction 80 W (14µF)
• Compact fluorescent lamps: 30 W
• LED lamps (<2W):
LED lamps (>2 W < 8 W): 20 W
• Permissible ambient temperature:
• Protection class:
• Protection rating:
• Time accuracy:
• Power reserve:
• Pollution degree:
• Rated impulse withstand voltage: 4 kV
• Max. switching cycles with 16 A
resistive load:
(TR 609 top2 S: 1300 W
(140 µF))
(TR 609 top2 S: 300 W)
6 W (TR 609 top2 S: 55 W)
(TR 609 top2 S: 180 W)
–25 °C ... +55 °C
II in accordance with
EN 60730-1 subject to
designated installation
IP 20 nach EN 60529
≤ ±0,25 s/day at 25 °C
10 years (lithium cell)
at +20 °C
2
50,000
23
GB