6. Technical data

Operating voltage:
Frequency:
Standby (6110130, 6220130):
Standby (6110330):
Max. switching capacity:
Switching capacity:
Min. switching capacity:
Switch output
(6110330/6220130):
TR 611top3 (6110130):
Shortest switching time:
Switching accuracy:
Protection rating:
Protection class:
Software:
Operating temperature:
Power reserve:
Time accuracy (typical):
Rated impulse voltage:
Pollution degree:
230 V AC, +10% / –15%
110 - 230 V AC (6110330)
50–60 Hz
0.4 W
0.75 W
16 A (at 250 V, cos ϕ = 1)
10 A (at 250 V, cos ϕ = 0.6)
10 mA/230 V AC
100 mA/24 V AC/DC
Switching of any external
conductor is permitted
Suitable for switching SELV
(Safety Extra-Low Voltage)
1 min
To the second
IP 20 in accordance with
EN 60529
II in accordance with
EN 60730-1 subject to
designated installation
Class A
6110330: -25 °C ... + 55 °C
6110130: -30 °C ... + 60 °C
6220130: -30 °C ... + 55 °C)
10 years at +20 °C (without
Bluetooth OBELISK top3)
± 0.25 s/day (25 °C)
4 kV
2