Parameter 25 To 35; Parameters 36 To 80 - Emerson Commander SX Advanced User's Manual

Ip66/nema 4x variable speed drive
Table of Contents

Advertisement

CONTROL TECHNIQUES
MENU 0 CORRESPONDENCE AND AUTOMATIC PARAMETER SETTING

2.3 - Parameter 25 to 35

Parameter
25
Operating mode
• If 25 = OP.LP (0 or 1)
Parameter
26
Open loop mode select
• If 26 = r.run (0) or r.no (1) or r.FSt (3) or r.On (4)
or SqrE (5)
27
to
Not used
30
31
Current loop P gain
32
Current loop I gain
33
to
Not used
35
• If 26 = UtoF (2)
27
and
Not used
28
29
Boost
30
Dynamic V to F
31
to
Not used
35
• If 25 = cL.LP (2) or SrvO (3)
Parameter
26
Encoder type
27
Encoder lines per revolution
28
Drive encoder filter
29
Speed loop P gain Kp1
30
Speed loop I gain Ki1
31
Current loop P gain
32
Current loop I gain
33
Ramp bypass
34
and
35
20
ADVANCED USER GUIDE
Commander SX
IP66/Nema 4X variable speed drive
Name
Address
11.31
Name
Address
5.14
4.13
4.14
5.15
5.13
Name
Address
3.38
3.34
3.42
3.10
3.11
4.13
4.14
2.02
Not used

2.4 - Parameters 36 to 80

Parameter
36
Brake controller enable
37
Upper current threshold
38
Lower current threshold
39
Brake release frequency
40
Brake apply frequency
41
Brake apply/magnetisation delay
42
Post-brake release delay
43
Brake apply delay
44
Not used
45
Not used
46 *
Start/stop logic select
47 *
Secure disable select
48 *
ADIO3 mode
49 *
ADIO3 feature
50 *
DIO1 feature
51 *
Jog reference
52 *
Bipolar reference enable
53 *
Skip (critical speed)
54 *
Skip reference band
55 *
Deceleration ramp mode select
56 *
S ramp enable
57 *
Stop mode
58 *
Mains loss mode
59
Catch a spinning motor
60
Maximum switching frequency
61
Motor rated frequency
62
Number of motor poles
63
Autotune
64
Parameter cloning
65
Factory setting
66
User security code
67
Parameter displayed at power-up
68
Selection of load display
69
Speed display unit
70
Parameter scaling
71
Last trip
72
Penultimate trip
73
ADI1 input level
74
ADI2 input level
75
ADIO3 input or output level
76
Pre-offset reference
77
Pre-ramp reference
78
Current magnitude
79
Motor speed
80
DC bus voltage
(*) For preset configuration 05 = Pump, the addresses for 46
to 58 are different.
See section 2.2.9 - Internal setting.
3854 en - 03.2008 / b
Name
Address
12.41
12.42
12.43
12.44
12.45
12.46
12.47
12.48
12.49
6.04
8.10
7.15
7.33
8.41
1.05
1.10
1.29
1.30
2.04
2.06
6.01
6.03
6.09
5.18
5.06
5.11
5.12
11.42
11.43
11.30
11.22
4.21
5.34
11.21
10.20
10.21
7.01
7.02
7.03
1.60
1.03
4.01
5.04
5.05