16.Electrical System

Battery

SAFETY FIRST: Protective gloves and eyewear are recommended at this point.
General Information
The KYMCO MXU 700i uses a GTX20L-BS 12V, battery.
ITEM
Capacity
Current leakage
Battery
Voltage (20°C/68°F)
Charging current
After being in service, batteries require regular cleaning and recharging in order to deliver
peak performance and maximum service life.
The following procedure is recommended for cleaning and maintaining lead-acid batteries.
Always read and follow instructions provided with battery chargers and battery products.
Warning: Anytime service is performed on a battery, the following must be observed: keep
sparks, open flame, cigarettes, or any other flame away. Always wear safety glasses.
Protect skin and clothing when handing a battery. When servicing battery in enclosed
space, keep the area well-ventilated.
1. Always remove the negative battery lead first.
2. Remove the battery from the battery compartment.
3. Thoroughly wash the battery and battery compartment with soap and water. NOTE: If
battery posts, cable ends, or the battery case has a build-up of white/green powder residue,
apply water and baking soda to neutralize acid; then flush off with warm soapy water.
4. Using a wire brush, clean the battery posts and cable ends removing all corrosive
buildup. Replace damaged cables or cable ends.
SPECIFICATIONS
12V-18 Ah
0.5 Ma max.
Full charge
13.0 - 13.2 V
Needs charging
Below 12.3 V
Normal
1.8 A/5 - 10 h
Quick
9 A/1 h
16-8