Reduced Gas Flow Rate Setting For Hob Taps - Samus SM450 Series User Manual

Gas & electrical oven, free standing
Table of Contents

Advertisement

Available languages

Available languages

1. Please use driver with special
head for removed and install nozzle as (Figure-8)
2. Please remove nozzle (Figure -9)
from burner with special nozzle driver
and install new nozzle (Figure -10)
Figure-8

REDUCED GAS FLOW RATE SETTING FOR HOB TAPS

1. Ignite the burner that is to be adjustment and turn the knob to the
reduced position.
2. Remove the knob from the gas tap.
3. Use an appropriately sized screwdriver to adjust the flow rate adjustment screw.
For LPG (Butane - Propane) turn the screw clockwise. For the naturel
gas, you should turn the screw counter- clockwise once.
"The normal length of a straight flame in the reduced position should be 6-7 mm.
4. If the flame is higher then the desired position, turn the screw clock-
wise. If it is smaller turn anticolockwise.
5. For the last control, bring the burner both to higt-flame and reduced
positions and check whether the flame is on or off.
Depending on the type of gas tap used in your appliance the adjustmenr
screw position may vary.
Figure-9
Figure-11
GB
Figure-10
21
Figure-12

Advertisement

Chapters

Table of Contents
loading

Table of Contents