STEP 5

FABRICATE SILL MEMBERS

-For end reactions over 500 lbs., fabricate sill members for anchoring to sill flashing:
-Measure in 6" from each end of the sill member and mark hole locations along the
"V"-groove as shown in Detail 7.
-Mark additional hole locations a maximum of 24" on center (O.C.).
-Drill a 0.213" diameter (#3 drill bit) hole at each location marked.
-If end reaction is under 500 lbs., one (1) .213" dia. weep hole is required at the center of
each daylight opening.
See Detail 7.
" 6
M
a
STEP 6
FABRICATE SILL FLASHING
For elevations without door framing:
-Cut sill flashing, E9-1068 to the frame width + 1/4.
For elevations with door framing:
-Cut the sill flashing from the end of the frame to the door jamb.
(See approved shop drawings for this dimension)
See Detail 8.
Page-12
FRAME FABRICATION
"V"-Groove
. x
24" Max.
Daylight Opening (D.L.O.)
YES 45 FS/FI Storefront System
0.213" Dia.
Typical
24" Max.
" 6
M
a
. x
02-4001-09 | Effective Date: May 29, 2018
E9-1069
Sill Member
DETAIL 7