Modifying Quorum Server Information - Huawei OceanStor 2000 V3 Series Features Manual

Hypermetro feature guide for file
Hide thumbs Also See for OceanStor 2000 V3 Series:
Table of Contents

Advertisement

OceanStor V3 Series
HyperMetro Feature Guide for File
Table 5-10 Quorum server link parameters
Parameter
Controller
Port
IP Address
Running Status
----End

5.1.4.2 Modifying Quorum Server Information

Through this operation, you can modify the properties of a quorum server and authentication
information for connecting the quorum server.
Procedure
Step 1 Log in to DeviceManager.
Step 2 Choose
Step 3 Select a quorum server that you want to modify and click Properties.
The Quorum Server Properties dialog box is displayed.
Step 4 On the General and Settings tab pages, modify the quorum server information.
explains the related parameters.
Table 5-11 Quorum server parameters
Parameter
Name
Description
Active IP Address
Primary Port
Issue 05 (2018-01-30)
Data Protection >
Description
Name of a quorum server.
Description of a quorum
server.
Primary IP address of a
quorum server.
Primary port ID of a quorum
server. The default port ID is
30002.
NOTE
The port ID ranges from 1 to
65535.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Description
Controller of a local device connecting to a
quorum server.
Controller port of a local device connecting
to a quorum server.
The IP address of a quorum server.
Running status of a link.
HyperMetro >
Quorum Server.
5 Management
Table 5-11
Example Value
[Example]
QuorumServer_001
[Example]
None
[Example]
192.168.0.1
[Example]
30002
155