Av System; Annular Buffers Between - Stihl MS 650 Manual

Hide thumbs Also See for MS 650:
Table of Contents

Advertisement

: Position the anchor loop about
25 mm from the edge of the
spring housing.
: Fit the rewind spring in the spring
housing in the counterclockwise
direction, starting from outside
and working inwards.
– Place the spring housing in the
fan housing.
– Press the spring loop into the
recess in the fan housing at the
same time.
– Install the rope rotor – b 8.4
– Tension the rewind spring –
b 8.6
Reassemble all other parts in the
reverse sequence.
MS 650, MS 660
9.

AV System

The crankcase and tank housing
are connected by vibration damping
rubber buffers and springs.
Damaged rubber buffers (annular
buffers) and springs must always be
replaced in sets.
– Remove the front handle –
b 10.3
– Remove the air filter – b 12.2.1
– Remove the shroud – b 6.2
– Remove the fan housing with
rewind starter –
b 8.2
– Remove the chain catcher –
b 5.2
9.1

Annular Buffers between

Crankcase and Tank
Housing
Removing at clutch side
: Pry the plugs (arrows) out of the
annular buffers.
: Take the screws out of the
annular buffers.
: Pry the annular buffers (arrows)
out of the crankcase.
63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ms 660

Table of Contents