Component
Generator
Generator
102
Ohmmeter connection
(use either test lead)
Lead 1
Lead 2
Connector
Ground
on yellow
wire
Connector
Connector
on yellow
on red
wire
wire
Resistance Ω
If faulty
Spec.
Actual
Cause
0.5
0.3...1.0 Generator OK
-
Break in wire,
generator damaged
0
Short circuit –
damaged insulation
1.0
0.8...1.8 Generator OK
-
Break in wire,
generator damaged
0
Short circuit –
damaged insulation
Remedy
Install new
generator
Repair
insulation
Install new
generator
Install new
generator