  • Page 1 October 2018 Rotor-Gene ® Q MDx Installation Guide (US) For use with Rotor-Gene Q Software version 2.3.4 or higher QIAGEN GmbH, QIAGEN Strasse 1, 40724 Hilden, GERMANY Sample & Assay Technologies...
  • Page 2 QIAGEN Sample and Assay Technologies QIAGEN is the leading provider of innovative sample and assay technologies, enabling the isolation and detection of contents of any biological sample. Our advanced, high-quality products and services ensure success from sample to result. QIAGEN sets standards in: Purification of DNA, RNA, and proteins ...
  • Page 3: Table Of Contents

    Launching Rotor-Gene Q Software Rotor-Gene Q Software Assay Packages Launching Rotor-Gene AssayManager Rotor-Gene AssayManager Assay Profiles and Plug-ins Configuration for Windows 7 security Additional Software on Computers Connected to Rotor-Gene Q MDx Instruments Antivirus software System tools Operating system updates...
  • Page 4: Product Warranty And Satisfaction Guarantee

    Should any product fail to perform satisfactorily due to any reason other than misuse, QIAGEN will replace it free of charge or refund the purchase price. We reserve the right to change, alter, or modify any product to enhance its performance and design.
  • Page 5: Introduction

    Introduction About this installation guide This guide provides an overview for installing Rotor-Gene Q MDx instruments. Rotor-Gene Q MDx User Manual (US) Note: Please consult the for additional details regarding installation, such as site and AC power requirements. Pay particular attention to the safety information.
  • Page 6: Unpacking The Rotor-Gene Q Mdx

    Once all these components have been removed from the box, remove the foam packing on top of the Rotor-Gene Q MDx. Carefully remove the Rotor-Gene Q MDx from the box and unwrap the plastic cover. Open the lid by sliding it towards the back to access the reaction chamber.
  • Page 7: Hardware Installation

    Allow the instrument to acclimatize to room temperature for at least one hour before turning the instrument on. 1. Place the Rotor-Gene Q MDx on a level surface that is vibration free. Note: Ensure that there is sufficient space behind the instrument for the lid to open fully.
  • Page 8 (advanced users only)” via a drop-down list. Select “Force authentication through Windows domain (advanced users only)” if you want to use the advanced security features (see section on Rotor-Gene Q MDx User Manual (US) “Access Protection” in the Rotor-Gene Q MDx Installation Guide (US) 10/2018...
  • Page 9: Connecting The Laptop/Computer To The Rotor-Gene Q Mdx

    Connecting the Laptop/Computer to the Rotor-Gene Q MDx USB connection for Rotor-Gene Q software and Rotor-Gene AssayManager We recommend connecting the laptop computer, which was delivered with your Rotor-Gene Q MDx, via the USB port. Rotor-Gene Q MDx Installation Guide (US) 10/2018...
  • Page 10 1. Connect one end of the provided USB cable to a USB port at the back of the computer. Connect the other end of the USB cable to the back of the Rotor-Gene Q MDx. Then connect the Rotor-Gene Q MDx to the power supply.
  • Page 11: Rs-232 Connection For Rotor-Gene Q Software

    1. Connect one end of the provided RS-232 serial cable to the serial port of your computer. Connect the other end of the RS-232 serial cable to the back of the Rotor-Gene Q MDx. Then connect the Rotor- Gene Q MDx to the power supply.
  • Page 12: Launching Rotor-Gene Q Software

    Instructions for Use (Handbook) for the assay you are using. Launching Rotor-Gene AssayManager To launch Rotor-Gene AssayManager, see the “Rotor-Gene AssayManager Core Application User Manual (US) IVD” in Part II of Volume 2 of the QIAsymphony RGQ MDx (US) User Manual Rotor-Gene Q MDx Installation Guide (US) 10/2018...
  • Page 13: Rotor-Gene Assaymanager Assay Profiles And Plug-Ins

    (US) IVD” in Part II of Volume 2 of the Manual Configuration for Windows 7 security The laptop computers that are provided by QIAGEN for use with your Rotor- Gene Q MDx instrument have Microsoft ® Windows 7 preinstalled and are configured with a standard (nonadministrative) Windows user account and with an administrator account.
  • Page 14: Additional Software On Computers Connected To Rotor-Gene Q Mdx Instruments

    Rotor-Gene Q software. It is particularly important to pay attention to the points listed below. System administrators are advised to consider any impact that a modification to the system may have on the resources before implementing it. Rotor-Gene Q MDx Installation Guide (US) 10/2018...
  • Page 15: Antivirus Software

    Antivirus software QIAGEN is aware of the threat that computer viruses pose to any computer that exchanges data with other computers. Rotor-Gene AssayManager version 1.0 or 2.1 software is expected to be primarily installed in environments where local policies are in place to minimize this threat. However, QIAGEN recommends the use of antivirus software in any case.
  • Page 16 The Rotor-Gene Q software can run either on computers without network access or in a network environment if a remote database server is used. For networked operation, the firewall on the laptop computer provided by QIAGEN is configured in a way that inbound traffic is blocked for all ports except those required to establish a network connection.
  • Page 17 3. Check that the following settings are active: For security and reliability reasons, cable-based network access instead of Wi-Fi shall be used. The laptop computers that are provided by QIAGEN have a disabled Wi-Fi adapter. If your configuration is different, a system administrator must disable the Wi-Fi adapter manually.
  • Page 18 2. Select “Change adapter settings”. 3. Hover over “Wireless Network Connection”, press the right mouse button, and select “Disable” from the context menu. Rotor-Gene Q MDx Installation Guide (US) 10/2018...
  • Page 19: System Tools

    Tools may be released that are not known at the time of writing. It is important that system administrators take care that such tools are not active on the Rotor-Gene Q MDx during a PCR run. Operating system updates The laptop computers provided by QIAGEN are configured such that automatic updates of the operating system are disabled.
  • Page 20 1. Open the Control Panel and select “Windows Update”. 2. Select “Change settings”. Rotor-Gene Q MDx Installation Guide (US) 10/2018...
  • Page 21 4. Check that the “Important updates” option “Never check for updates” is active. QIAGEN designed the QIAGEN System Updater to facilitate Windows updates in a controlled manner. The QIAGEN System Updater is only for use with your QIAGEN laptop computer, in conjunction with Microsoft Windows 7 or Microsoft Windows 10.
  • Page 22: Updating Rotor-Gene Q Software And Rotor-Gene Assaymanager Software

    The QIAGEN System Updater and the corresponding instructions for use can be downloaded from www.qiagen.com. The instructions for use will provide a guide for the installation and usage of the QIAGEN System Updater. Updating Rotor-Gene Q Software and Rotor-Gene AssayManager Software Software updates are available from QIAGEN at www.qiagen.com/products/rotor-geneqmdx.aspx for Rotor-Gene Q software...
  • Page 23 Trademarks: QIAGEN ® ® ® ® ® ® , Rotor-Gene , Rotor-Gene AssayManager (QIAGEN Group); Microsoft , Windows (Microsoft Corporation); Symantec (Symantec Corporation). Oct-18 HB-1019-004 © 2012–2018 QIAGEN, all rights reserved.
  • Page 24  Ordering www.qiagen.com/shop | Technical Support support.qiagen.com | Website www.qiagen.com Sample & Assay Technologies 1114364EN 10/2018...