H3C S5500-EI Series Operation Manual page 194

Hide thumbs Also See for S5500-EI Series:
Table of Contents

Advertisement

Operation Manual – Multicast
H3C S5500-EI Series Ethernet Switches
5)
Verify the configuration
You can use the display msdp brief command to view the brief information of MSDP
peering relationships between the switches.
# View the brief MSDP peer information on Switch B.
[SwitchB] display msdp brief
MSDP Peer Brief Information
Configured
1
Peer's Address
2.2.2.2
# View the brief MSDP peer information on Switch D.
[SwitchD] display msdp brief
MSDP Peer Brief Information
Configured
1
Peer's Address
1.1.1.1
To view the PIM routing information on the switches, use the display pim
routing-table command. When Source 1 (10.110.5.100/24) sends multicast data to
multicast group G (225.1.1.1), Receiver 1 joins multicast group G. By comparing the
PIM routing information displayed on Switch B with that displayed on Switch D, you can
see that Switch B acts now as the RP for Source 1 and Receiver 1.
# View the PIM routing information on Switch B.
[SwitchB] display pim routing-table
Total 1 (*, G) entry; 1 (S, G) entry
(*, 225.1.1.1)
RP: 10.1.1.1 (local)
Protocol: pim-sm, Flag: WC
UpTime: 00:15:04
Upstream interface: Register
Downstream interface(s) information:
Total number of downstreams: 1
Up
1
State
Up
Up
1
State
Up
Upstream neighbor: NULL
RPF prime neighbor: NULL
1: Vlan-interface100
Protocol: igmp, UpTime: 00:15:04, Expires: -
Listen
Connect
0
0
Up/Down time
AS
00:10:17
?
Listen
Connect
0
0
Up/Down time
AS
00:10:18
?
8-30
Chapter 8 MSDP Configuration
Shutdown
Down
0
0
SA Count
Reset Count
0
0
Shutdown
Down
0
0
SA Count
Reset Count
0
0

Advertisement

Table of Contents
loading

Table of Contents