Change Touch Screen Sensitiveness

Raw Data

You can check the sensitivity and noise level.
Clean Data
This shows the sensitivity (gain) after filtering
Sensitivity, threshold and noise level should be checked on this
screen.
72E0: Product ID of
the controller board
Initialize the controller and calibrate
the hardware at the same time
Measure the Stray Capacitance with chassis and re-set the filter
value automatically. Do not touch the sensor when executing it
80
Gain (min) = Threshold value x around 2
The best threshold level we recommend
is the gain devided by 2
(e.g. If the gain is 1000, the threshold
should be set to 1000/2=500)