Multiplex drain/overflow functional unit (17 pages)
Summary of Contents for Viega 8326.1
Page 1
Flush plate Visign for Public 1 Instructions for Use for concealed cistern 2H, concealed cistern 2L, concealed cis- tern 2C, concealed cistern Standard 2S Model Year built: 8326.1 from 01/2011 en_INT...
Page 2
Flush plate Visign for Public 1 2 from 20...
Table of contents Table of contents About these instructions for use Target groups Labelling of notes About this translated version Product information Intended use 2.1.1 Areas of use Product description 2.2.1 Overview 2.2.2 Technical data Handling Assembly information 3.1.1 Required material and tools Assembly 3.2.1 Prepare cistern...
This restriction does not extend to possible operating instructions. The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
About these instructions for use About this translated version This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e.
2 Product information Intended use 2.1.1 Areas of use Suitable cisterns The flush plate is intended for the actuation of flushes on Viega con- cealed cisterns. Installation is only possible in the following Viega concealed cisterns: Cistern model 2H Cistern model 2L Ascertain which model is installed before mounting.
Product information Product description 2.2.1 Overview Fig. 1: Component overview 1 - basic panel 2 - holding panel 3 - flush plate with fixing screws 4 - actuating rod 5 - threaded bolt 2.2.2 Technical data The product exhibits the following technical data: Flush volume A flush with the large flush volume is always released via the flush plate.
Handling 3 Handling Assembly information 3.1.1 Required material and tools Tool The following tools are required for mounting: flat screwdriver Torx screwdriver (T 10) knife (cutter) Assembly 3.2.1 Prepare cistern The following work stages and diagrams differ depending on the cistern being used. The relevant steps are marked accordingly.
Page 9
Handling Remove shaft cover. Score the revision shaft along the edge of the tiles with a knife. Angle the knife to do this so that the cut is made flush to the surface of the wall. Cut the corners of the revision shaft vertically through to the wall surface.
Page 10
Handling Remove cistern cover. Remove and keep the threaded bolts from the cistern cover. Keep cistern casing. INFO! Only for assembly of the flush plate in cistern 2H or on the front of cistern 2L. Press the bow backwards from the mounting of the mechanism. INFO! Only for assembly of the flush plate on the top of cistern Press the bow backwards from the mounting of the mechanism.
Page 11
Handling Remove and keep mechanism. Flush pipelines (cistern 2H) Requirements: The revision shaft is shortened in such a way that it is flush with the surface. Mechanism has been removed. Close corner valve. Loosen flexible hose on the filling valve (SW 19). Flush plate Visign for Public 1 11 from 20...
Page 12
Handling Open the corner valve for a few seconds to rinse the pipe. Re-close corner valve. Connect the flexible hose onto the filling valve (SW 19). Open corner valve. Flush plate Visign for Public 1 12 from 20...
Page 13
Handling Flush pipelines (cistern 2L) Requirements: The revision shaft is shortened in such a way that it is flush with the upper edge of the tiles. Mechanism has been removed. Close corner valve. Loosen flexible hose on the filling valve (SW 19). Open the corner valve for a few seconds to rinse the pipe.
Handling Connect the flexible hose onto the filling valve. Open corner valve. 3.2.2 Mount flush actuation Mount mechanism (cistern 2H) Hang the mechanism in the bow of the drain valve. Flush plate Visign for Public 1 14 from 20...
Page 15
Handling Insert mechanism. The mechanism must sit exactly in the recesses in the cistern. Turn the mechanism's lock by 90° in a clockwise direction. ð The mechanism is locked. Mount mechanism (cistern 2L) How to install the mechanism depends on whether the flush plate is to be fitted to the front or top of the cistern.
Page 16
Handling Insert mechanism. The mechanism must sit exactly in the recesses in the cistern. Turn the mechanism's lock by 90° in a clockwise direction. ð The mechanism is locked. Horizontal installation (flush plate on the top of the cistern) Hang the mechanism in the bow of the drain valve. Flush plate Visign for Public 1 16 from 20...
Handling Insert mechanism. In doing so, ensure that the tracks on the top and bottom edge of the mechanism are in the indentations in the revision shaft of the cistern. Turn the mechanism's lock by 90° in a clockwise direction. ð...
Page 18
Handling Insert the threaded bolts so deeply that the upper edge of the threaded bolt sticks out approx. 15 mm behind the upper edge of the tiles. Secure threaded bolts with a 90° turn. Screw actuating rod into the tapped hole. Set the screw-in depth flush with the upper edge of the tiles with the help of the template supplied.
Handling Mount holding plates and basic panels. Mount and screw flush plate tight. Commissioning 3.3.1 Setting the flush Set the flush volume on the drain valve of the cistern. Large flush volume: approx. 6–9 litres Error, faults and remedy Error Cause Remedy WC does not flush...
Handling Error Cause Remedy Dirty seal in drain valve Check seal, replace if necessary WC flush actuation does not work The mechanism is not connected Hang the mechanism in the bow to the bow Care and maintenance 3.5.1 Maintenance tips Normal soap or a mild cleaning agent can be used for regular care and prevention of lime scale on the flush plate.