Remote Control Installation; Remote Control Settings - Thermoscreens T Series Operation And Maintenance

Recessed range
Table of Contents

Advertisement

9.

REMOTE CONTROL INSTALLATION

Mount the remote control unit in a convenient position directly to the wall or onto a switch box.
9.1
Wall mounting
Step 1 Using a screwdriver undo the screw on the top of the remote control
case and pull the back case away (see Fig 12).
Step 2 Feed one end of the RJ control cable through the back case, secure it,
then screw the back case to the wall using suitable fixings (not
supplied).
Step 3 Connect the RJ plug to the RJ socket on the PCB in the remote control.
Step 4 Refit the front case.
9.2
Switch box mounting
Step 1 Using a screwdriver undo the screw on the top of the remote control case and pull the back
case away (see Fig 12).
Step 2 Feed one end of the RJ control cable through the switch box, feed and
secure the RJ control cable through the back case and secure back
case to switch box using 2 x M3.5 screws (not supplied) (see Fig 13).
Step 3 Connect the RJ plug to the RJ socket on the PCB in the remote control.
Step 4 Refit the front case.
NOTE: For optional remote control settings, see section 10.

10. REMOTE CONTROL SETTINGS

On the back of the PCB inside the Ecopower Remote Control you will find four DIP switches that
provide the following optional features, see Table 3.
DIP
Feature
1
Reset on power-up
2
Stop fan on cold
3
Never blow cold
4
Room air
temperature control
T9901012-1-1 UK (v9)
Explanation
On restoring power after an
electrical interruption all Remote
Control settings are retained
Fans are switched off when
heating level is achieved (AUTO
mode only)
Air curtain always heats in
AUTO mode
Enables the room air sensor in
the Remote Control
Fig 12
Fig 13
Default
Notes
ON
WARNING! – Fans start
on their own after power
is restored
OFF
OFF
Will not go to ambient
mode
OFF
Disables all other
temperature sensors
Table 3
Page | 10