Code Description
Reference measurement on the dark
2401
reference element
Reference measurement on the dark
2401
reference element
Reference measurement on the light ref-
2402
erence element
Processing of messages for
2701
system diagnostics
Processing of requests for diagnostic
2702
data
Processing of the inputs for detection
2800
field switching
Processing of the inputs for detection
2800
field switching
Processing of the inputs for detection
2800
field switching
Processing of the inputs for detection
2800
field switching
Test of the inputs for
2801
detection field switching
Initialisation of
2802
detection field changeover
Initialisation of
2802
detection field changeover
Initialisation of
2802
detection field changeover
Initialisation of
2802
detection field changeover
Monitoring of the access authorisation
3016
with one-time password
Table 10.2:ROD4...plus - Diagnostic codes and causes
Leuze electronic
Status messages, errors and error rectification
No Error description
No distance value can be calculated for
reference measurement; glare from other
10
light sources (905nm) or rotational speed
deviation
No distance value can be calculated for
reference measurement; dust in device
13
because connector housing or dummy cap
not screwed down
No distance value can be calculated for
reference measurement; glare from other
10
light sources (905nm) or rotational speed
deviation
Invalid diagnostic command received, soft-
1
ware incompatible with firmware
Invalid diagnostic value requested, soft-
3
ware incompatible with firmware
2
2 detection fields active for longer than 1s
The detection field switching which
3
occurred does not match the preset which
was programmed in the ROD4...plus
More than 2 detection fields selected dur-
4
ing operation
Unusable data or inadequate data quality
6
for detection field activation
Error while testing the inputs for detection
1
field switching; internal defect
The detection field activation which
3
occurred does not match the preset which
was programmed in the ROD4...plus
More than 2 detection fields selected dur-
4
ing power-on
Unusable data or inadequate data quality
6
for detection field activation
No detection field activated during start-up
8
of the ROD4...plus
Confirmed single password has been
11
entered incorrectly
ROD4... plus
53